Autoactivation of source dwell positions for HDR brachytherapy treatment planning.
نویسندگان
چکیده
The most accurate classical dose optimization algorithms in HDR brachytherapy strongly depend on an appropriate selection of source dwell positions which fulfill user-defined geometrical boundary conditions which are relative to patient anatomy. Most anatomical situations, such as for prostate and head and neck tumors, are complex and can require geometries with 5-15 catheters with 48 possible dwell positions per catheter depending on the tumor volume. The manual selection of dwell positions using visual checks by trial and error is very time consuming. This can only be improved by the use of a technique which automatically recognizes and selects the optimum dwell positions for each catheter. We have developed an algorithm, termed an autoactivation algorithm, which improves implant planning by providing a facility for the necessary automatic recognition of HDR source dwell positions.
منابع مشابه
Design and Implementation of a Complementary Treatment Planning Software for the GZP6 HDR Brachytherapy System (GZP6 CTPS)
Introduction: Brachytherapy is one of the most common treatment modalities for gynecological cancer. The GZP6 brachytherapy system is one of the devices utilized in Iran. It has been considered particularly due to its low cost compared to other more complete and established systems. This system has some deficiencies including lack of a treatment planning software for non-predefined treatments, ...
متن کاملIndependent assessment of source transit time for the BEBIG SagiNova® high dose rate brachytherapy afterloader
Introduction: The dwell time and transit time components contribute to the overall delivered dose to patients in high dose rate (HDR) brachytherapy treatments. The transit time results from source entry and exit as well as source movements between dwell positions. It depends on various parameters such as the source speed profile, source indexer distance to dwell position, and ...
متن کاملA dwell position verification method for high dose rate brachytherapy
Misplacement of dwell positions is a potential source of misadministration in high dose rate brachytherapy. In this work we present a dwell position verification method using fluoroscopic images. A mobile C-arm fluoroscopic machine is used to take a snapshot of the treatment machine's check cable as it reaches the most distal dwell position. This fluoroscopic image is displayed side-by-side wit...
متن کاملComparison the treatment time of cobalt and iridium sources in HDR brachytherapy
Introduction: The use of long-half-life Cobalt source instead of iridium source will be very helpful in HDR brachytherapy for treatment of cervical cancer. The aim of this study was compared the treatment time with cobalt and iridium source in brachytherapy for treatment of cervical cancer using Tandem-ovoid applicator. Materials and Methods: In this study, 19...
متن کاملTandem-ring dwell time ratio in Nigeria: dose comparisons of two loading patterns in standard high-dose-rate brachytherapy planning for cervical cancer
PURPOSE In high-dose-rate (HDR) brachytherapy (BT), the source dwell times and dwell positions are essential treatment planning parameters. An optimal choice of these factors is fundamental to obtain the desired target coverage with the lowest achievable dose to the organs at risk (OARs). This study evaluates relevant dose parameters in cervix brachytherapy in order to assess existing tandem-ri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 27 11 شماره