Image contrast model of non-line-of- sight imaging based on laser range- gated imaging
نویسندگان
چکیده
Laser range-gated imaging systems can obtain images of targets hidden around the corner, with an intermediary reflective surface with certain specular reflection characteristics. This imaging mode is called nonline-of-sight imaging. This paper describes a simulation of the target signal illuminance and disturbance radiation on the photosensitive surface of a non-line-of-sight imaging system based on modeling of an intermediary reflective surface. Meanwhile, an image contrast model of a non-line-of-sight imaging system is constructed. Simulation of the image contrast for a laser range-gated imaging system as a non-line-of-sight imaging equipment was carried out by analyzing the effects of varying the target signal illuminance and intermediary reflective surface reflection. Our simulation results show that the reflection characteristics of the intermediary reflective surface have a significant effect on the non-line-of-sight imaging. Although ordinary active laser imaging can realize non-line-of-sight imaging for an intermediary reflective surface with significant specular reflection characteristics, a laser range-gated imaging system is indispensable for non-line-of-sight imaging with commonly used intermediary reflective surfaces without significant specular reflection characteristics. The image contrast model of non-line-of-sight imaging constructed in this paper provides insights into the theoretical analysis and system design, as well as practical application of non-line-of-sight imaging. © The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.OE.53.6.061610]
منابع مشابه
Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملAnalytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging
Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...
متن کاملRock mass structural characterization via short-range digital photogrammetry
Because of the important role of rock mass structural properties on its mechanical behavior, determining the qualitative and quantitative properties of has been a subject of intense research. In this regard, numerous techniques such as scanline surveying, cell mapping, and geologic structure mapping have been proposed. However, applying such field surveying techniques for rock mass properties i...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملApplications of gold nanoparticles for medical imaging
Background & Aim: Molecular imaging enables us to non-invasively visualize tissue microstructures and lesion characterization, allowing accurate diagnosis of diseases at early stages. A successful molecular imaging requires a nontoxic contrast agent with high sensitivity. Nowadays, a wide range of nanoparticles have been developed as contrast agents for medical imaging modalities. Here, we revi...
متن کامل