Estimating the accuracy of protein structures using residual dipolar couplings.
نویسندگان
چکیده
It has been commonly recognized that residual dipolar coupling data provide a measure of quality for protein structures. To quantify this observation, a database of 100 single-domain proteins has been compiled where each protein was represented by two independently solved structures. Backbone 1H-15N dipolar couplings were simulated for the target structures and then fitted to the model structures. The fits were characterized by an R-factor which was corrected for the effects of non-uniform distribution of dipolar vectors on a unit sphere. The analyses show that favorable R values virtually guarantee high accuracy of the model structure (where accuracy is defined as the backbone coordinate rms deviation). On the other hand, unfavorable R values do not necessarily suggest low accuracy. Based on the simulated data, a simple empirical formula is proposed to estimate the accuracy of protein structures. The method is illustrated with a number of examples, including PDZ2 domain of human phosphatase hPTP1E.
منابع مشابه
Theoretical analysis of residual dipolar coupling patterns in regular secondary structures of proteins.
A new approach to the interpretation of residual dipolar couplings for the regular secondary structures of proteins is presented. This paper deals with the analysis of the steric and chiral requirements of protein secondary structures and establishes a quantitative correlation between structure periodicity and the experimental values of the backbone residual dipolar couplings. Building on the r...
متن کاملDirect structure refinement against residual dipolar couplings in the presence of rhombicity of unknown magnitude.
Residual dipolar couplings arising from small degrees of alignment of molecules in a magnetic field provide unique long-range structural information. The potential of this approach for structure refinement has recently been demonstrated for a protein-DNA complex in which the magnetic susceptibility tensor was axially symmetric. For most macromolecules and macromolecular complexes, however, axia...
متن کاملEvaluation of uncertainty in alignment tensors obtained from dipolar couplings.
Residual dipolar couplings and their corresponding alignment tensors are useful for structural analysis of macromolecules. The error in an alignment tensor, derived from residual dipolar couplings on the basis of a known structure, is determined not only by the accuracy of the measured couplings but also by the uncertainty in the structure (structural noise). This dependence is evaluated quanti...
متن کاملA graphical method for analyzing distance restraints using residual dipolar couplings for structure determination of symmetric protein homo-oligomers.
High-resolution structure determination of homo-oligomeric protein complexes remains a daunting task for NMR spectroscopists. Although isotope-filtered experiments allow separation of intermolecular NOEs from intramolecular NOEs and determination of the structure of each subunit within the oligomeric state, degenerate chemical shifts of equivalent nuclei from different subunits make it difficul...
متن کاملCABM Symposium Complete protein structure determination using backbone residual dipolar couplings and sidechain rotamer prediction
Residual dipolar couplings provide significant structural information for proteins in the solution state, which makes them attractive for the rapid determination of protein structures. While dipolar couplings contain inherent structural ambiguities, these can be reduced via an overlap similarity measure that insists that protein fragments assigned to overlapping regions of the sequence must hav...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomolecular NMR
دوره 33 2 شماره
صفحات -
تاریخ انتشار 2005