Magnetization reversal of permalloy film by pure spin current injection: relation between reversal time and injected surface
The dynamics of the magnetization reversal process in a nanosized permalloy film by the pure spin current (PSC) injection is analyzed. We have performed micromagnetic simulation based on the Landau-Lifshitz equation taking into account both the relaxation term and spin transfer torque term caused by the PSC. PSC is injected into the permalloy from a side of the film. We compare the magnetizatio...
متن کاملSUEX Dry Film Resist – A new Material for High Aspect Ratio Lithography
SUEX epoxy Thick Dry Film Sheets (TDFS) are a promising material for a wide range of MEMS applications. They contain a cationically cured modified epoxy formulation utilizing an antimony-free photo acid generator (PAG). A highly controlled solvent-less process provides uniform resist coatings between two throw-away layers of protective polyester (PET) film in varying thicknesses ranging from 10...
متن کاملObservation of magnetization reversal of thin-film permalloy nanostructures using ballistic electron magnetic microscopy
We have imaged the magnetization reversal process of thin-film permalloy (Ni80Fe20) nanostructures using ballistic electron magnetic microscopy. Their switching behavior is often influenced by the formation of end domains and the subsequent domain-wall propagation under application of a magnetic field. Occasionally, this process leads to the formation of a 360° domain wall that is stable in fie...
متن کاملYoung’s modulus of electroplated Ni thin film for MEMS applications
The Young’s modulus of an electroplated nickel (Ni) thin film suitable for microelectromechanical applications has been investigated as a function of process variables: the plating temperature and current density. It was found that the Young’s modulus is approximately 205 GPa at plating temperatures less than 60 jC, close to that of bulk Ni, but drastically drops to approximately 100 GPa at 80 ...
متن کاملMagnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...