Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.

نویسندگان

  • Giulio Guagliumi
  • Giuseppe Musumeci
  • Vasile Sirbu
  • Hiram G Bezerra
  • Nobuaki Suzuki
  • Luigi Fiocca
  • Aleksandre Matiashvili
  • Nikoloz Lortkipanidze
  • Antonio Trivisonno
  • Orazio Valsecchi
  • Giuseppe Biondi-Zoccai
  • Marco A Costa
چکیده

OBJECTIVES We designed a randomized trial exploiting optical coherence tomography (OCT) to assess coverage and apposition of overlapping bare-metal stents (BMS) and drug-eluting stents (DES) in human coronary arteries. BACKGROUND Overlapping DES impair healing in animals. Optical coherence tomography allows accurate in vivo assessment of stent strut coverage and apposition. METHODS Seventy-seven patients with long coronary stenoses were randomized to overlapping sirolimus-eluting stents (SES), paclitaxel-eluting stents (PES), zotarolimus-eluting stents (ZES), or BMS. The primary goal of the study was to determine the rate of uncovered/malapposed struts in overlap versus nonoverlap segments, according to stent type, at 6-month follow-up with OCT. RESULTS A total of 53,047 struts were analyzed. The rate of uncovered/malapposed struts was 1.5 +/- 3.4% and 0.6 +/- 2.7% in overlap versus nonoverlap BMS (p = NS), respectively, and 4.3 +/- 11% and 3.6 +/- 8% in overlap versus nonoverlap DES (p = NS), respectively. There were no differences in the rates of uncovered/malapposed struts between overlapping BMS and DES, likely due to low frequency of uncovered/malapposed struts in ZES (0.1 +/- 0.4%), which offset the higher rates observed in SES (6.7 +/- 9.6%) and PES (6.7 +/- 16.5%, p < 0.05). Overlap segments showed greater neointimal volume obstruction versus nonoverlap segments in all DES (p < 0.05 for all DES types). Strut-level neointimal thickness at overlap and nonoverlap segments were lowest in SES (0.16 +/- 0.1 mm and 0.12 +/- 0.1 mm, respectively) compared with PES (0.27 +/- 0.1 mm and 0.20 +/- 0.1 mm, respectively), ZES (0.40 +/- 0.16 mm and 0.33 +/- 0.13 mm, respectively), and BMS (0.55 +/- 0.31 mm and 0.53 +/- 0.25 mm, respectively, p < 0.05). CONCLUSIONS As assessed by OCT the impact of DES on vascular healing was similar at overlapping and nonoverlapping sites. However, strut malapposition, coverage pattern, and neointimal hyperplasia differ significantly according to DES type. (Optical Coherence Tomography for Drug Eluting Stent Safety [ODESSA]; NCT00693030).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Formation and Transformation of Neointima after Drug-eluting Stent Implantation: Insights from Optical Coherence Tomographic Studies

After coronary stent implantation, neointima formation resembles the wound healing process as it involves the sequential processes of inflammation, granulation, and remodeling. Because antiproliferative drugs and polymers of drug-eluting stents (DESs) delay vascular healing compared with bare metal stents, fibrin deposition can remain long after stent implantation, or inflammation can be excess...

متن کامل

Venous drug-eluting vs. bare-metal stenting: an experimental animal study using frequency domain optical coherence tomography.

INTRODUCTION This protocol was designed to evaluate the safety and feasibility of implanting drug-eluting stents (DES), as well as to compare their long-term results versus bare-metal stents (BMS), in a rabbit venous model, using frequency-domain optical coherence tomography (FD-OCT). METHODS Thirteen New Zealand white rabbits underwent implantation of a zotarolimus-eluting stent in the iliac...

متن کامل

Tissue characterization after drug-eluting stent implantation using optical coherence tomography.

OBJECTIVE To validate optical coherence tomography (OCT) imaging for assessment of vascular healing in a preclinical animal model and human autopsy cases and to translate the findings to the assessment of vascular healing after drug-eluting stent implantation in clinical practice. APPROACH AND RESULTS Drug-eluting and bare metal stents were imaged 28 and 42 days after implantation in atherosc...

متن کامل

Effectiveness of Bare Metal Stent Implantation for the Treatment of Coronary Artery Aneurysm: A Multimodality Imaging Evaluation

Coronary artery aneurysm (CAA) after sirolimus-eluting stent (SES) implantation is one of the most troublesome problems associated with first-generation drug-eluting stents. However, the natural course and standard therapy of CAA has been unknown. A 49-year-old man underwent SES implantation for the left anterior descending artery. Follow-up coronary angiography (CAG) revealed CAA in the SES. W...

متن کامل

Comparison of Neointimal Tissue Characteristics Between Bare-metal and Second-generation Drug-eluting Stents Nine Months after Implantation in Patients with ST-segment Elevation Myocardial Infarction

Background: Neointimal tissue characteristics after implantation of stents are related to late/ very late stent thrombosis and/ or restenosis of target lesion. However, the difference of them has not been fully elucidated among bare-metal stents (BMS) and second-generation drug-eluting stents (DES). Methods: The present study uses optical coherence tomography (OCT) to compare neointimal tissue ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 3 5  شماره 

صفحات  -

تاریخ انتشار 2010