Development and Characterization of a Neutron Personal Dose Equivalent Monitor

نویسندگان

  • N. Tsujimura
  • T. Yoshida
  • T. Nunomiya
  • K. Aoyama
چکیده

The authors developed a new neutron-measuring instrument that was designed to measure a neutron personal dose equivalent, Hp(10). This instrument is composed of a conventional moderator-based neutron dose equivalent meter and a neutron shield made of borated polyethylene which covers a backward hemisphere to adjust the angular dependence. The whole design was determined on the basis of MCNP calculations so as to have response characteristics which would generally match both the energy and angular dependencies of Hp(10). The verification experiments for energy and angular responses were done using monoenergetic neutrons produced by the accelerator and polyenergetic neutrons from the moderated 252 Cf source. Experiments showed that the new instrument has reasonably acceptable responses as a reference neutron dosemeter. The authors conclude that this new instrument will be a great help in assessing the reference values of neutron Hp(10) during field testing of personal neutron dosemeters in the workplace and also in interpreting their readings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Neutron Dosimeter

Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...

متن کامل

Dose GRID increase the unwanted photoneutron dose to the patients in GRID therapy?

Introduction: GRID therapy is a treatment modality in which a high dose of radiation in a single fraction is given to the tumor. This technique previously was used to treat bulky tumors with orthovoltage beams. Recently, studies have been conducted to suggest that GRID therapy with megavoltage photons can be useful in palliative treatments. On the other hand, there has always ...

متن کامل

Assessment of secondary neutron dose due to dental restorations in head and neck radiation therapy

Introduction: One of scientific concern is increasing of unwanted neutron dose to the patient, in head and neck radiation therapy due to the presence of some isotopes in dental restorations and head of medical linac. The aim of this study is to measure the equivalent dose of thermal and fast neutron due to head of Siemens Primus Linac and a healthy tooth, Amalgam, Ni-Cr alloy a...

متن کامل

Monte Carlo characterization of photoneutrons in the radiation therapy with high energy photons: a Comparison between simplified and full Monte Carlo models

Background: The characteristics of secondary neutrons in a high energy radiation therapy room were studied using the MCNPX Monte Carlo (MC) code. Materials and Methods: Two MC models including a model with full description of head components and a simplified model used in previous studies were implemented for MC simulations. Results: Results showed 4-53% difference between full and wit...

متن کامل

Active Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran

Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008