Advanced physics and algorithms in the IBA DataFurnace

نویسندگان

  • N. P. Barradas
  • C. Jeynes
چکیده

The IBA DataFurnace (NDF) is a general purpose program for analysis of IBA data. It currently includes Rutherford backscattering (RBS), elastic (non-Rutherford) backsscattering (EBS), elastic recoil detection analysis (ERDA), non-resonant nuclear reaction analysis (NRA), and particle induced X-ray emission (PIXE). Here we discuss recent developments in the advanced physics capabilities implemented in NDF, supported by advanced algorithms. Examples of real life hard cases are given that illustrate the issues discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous PIXE and RBS data analysis using Bayesian Inference with the DataFurnace code

The Rutherford Backscattering Spectroscopy (RBS) and Particle Induced X-ray Emission (PIXE) techniques can be used to obtain complementary information about the characteristics of a sample but, traditionally, a gap has separated the available computer codes for analyzing data from each technique, being hard to simultaneously analyze data from the same sample. The recent development of a free an...

متن کامل

Dosimetric Evaluation of Dose calculation algorithms of Monaco Treatment Planning System in the heterogeneities area

Introduction: In radiation therapy, the accuracy of dose calculations by a treatment planning system (TPS) is important to achieve tumor control and to spare normal tissue. Treatment planning system calculations in the heterogeneous situation may present significant inaccuracies. In this study, three different dose calculation algorithms, pencil beam (PB), collapsed cone (CC), ...

متن کامل

Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms

Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...

متن کامل

Evaluation of Dose Calculation Algorithms Accuracy for Eclipse, PCRT3D, and Monaco Treatment Planning Systems Using IAEA TPS commissioning tests in a Heterogeneous Phantom

Introduction: The accuracy of dose calculation algorithm (DCA) is highly considered in the radiotherapy sequences. This study aims at assessing the accuracy of five dose calculation algorithms in tissue inhomogeneity corrections, based on the International Atomic Energy Agency TEC-DOC 1583. Material and Methods: A heterogeneous phantom was sc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012