EEG source analysis of epileptiform activity using a 1 mm anisotropic hexahedra finite element head model
نویسندگان
چکیده
The major goal of the evaluation in presurgical epilepsy diagnosis for medically intractable patients is the precise reconstruction of the epileptogenic foci, preferably with non-invasive methods. This paper evaluates whether surface electroencephalography (EEG) source analysis based on a 1 mm anisotropic finite element (FE) head model can provide additional guidance for presurgical epilepsy diagnosis and whether it is practically feasible in daily routine. A 1 mm hexahedra FE volume conductor model of the patient's head with special focus on accurately modeling the compartments skull, cerebrospinal fluid (CSF) and the anisotropic conducting brain tissues was constructed using non-linearly co-registered T1-, T2- and diffusion-tensor-magnetic resonance imaging data. The electrodes of intra-cranial EEG (iEEG) measurements were extracted from a co-registered computed tomography image. Goal function scan (GFS), minimum norm least squares (MNLS), standardized low resolution electromagnetic tomography (sLORETA) and spatio-temporal current dipole modeling inverse methods were then applied to the peak of the averaged ictal discharges EEG data. MNLS and sLORETA pointed to a single center of activity. Moving and rotating single dipole fits resulted in an explained variance of more than 97%. The non-invasive EEG source analysis methods localized at the border of the lesion and at the border of the iEEG electrodes which mainly received ictal discharges. Source orientation was towards the epileptogenic tissue. For the reconstructed superficial source, brain conductivity anisotropy and the lesion conductivity had only a minor influence, whereas a correct modeling of the highly conducting CSF compartment and the anisotropic skull was found to be important. The proposed FE forward modeling approach strongly simplifies meshing and reduces run-time (37 ms for one forward computation in the model with 3.1 million unknowns), corroborating the practical feasibility of the approach.
منابع مشابه
Numerical Mathematics of the Subtraction Method for the Modeling of a Current Dipole in EEG Source Reconstruction Using Finite Element Head Models
In electroencephalography (EEG) source analysis, a dipole is widely used as the model of the current source. The dipole introduces a singularity on the right-hand side of the governing Poisson-type differential equation that has to be treated specifically when solving the equation towards the electric potential. In this paper, we give a proof for existence and uniqueness of the weak solution in...
متن کاملHead model and electrical source imaging: A study of 38 epileptic patients☆
Electrical source imaging (ESI) aims at reconstructing the electrical brain activity from scalp EEG. When applied to interictal epileptiform discharges (IEDs), this technique is of great use for identifying the irritative zone in focal epilepsies. Inaccuracies in the modeling of electro-magnetic field propagation in the head (forward model) may strongly influence ESI and lead to mislocalization...
متن کاملA finite difference method with reciprocity used to incorporate anisotropy in electroencephalogram dipole source localization.
Many implementations of electroencephalogram (EEG) dipole source localization neglect the anisotropical conductivities inherent to brain tissues, such as the skull and white matter anisotropy. An examination of dipole localization errors is made in EEG source analysis, due to not incorporating the anisotropic properties of the conductivity of the skull and white matter. First, simulations were ...
متن کاملThe Finite Element Method in EEG / MEG Source Analysis
Electroand magnetoencephalography (EEG/MEG)-based source reconstruction of cerebral activity (the EEG/MEG inverse problem) is an important tool both in clinical practice and research and in cognitive neuroscience. Methods for solving the inverse problem are based on solutions to the corresponding forward problem, i.e., simulation of EEG/MEG fields for a given primary source in the brain with a ...
متن کاملInfluence of anisotropic conductivity of the white matter tissue on EEG source reconstruction – a FEM simulation study
The aim of this study was to quantify the influence of the inclusion of anisotropic conductivity on EEG source reconstruction. We applied high-resolution finite element modeling and performed forward and inverse simulation with over 4000 single dipoles placed around an anisotropic volume block (with an anisotropic ratio of 1:10) in a rabbit brain. We investigated three different orientation of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 44 2 شماره
صفحات -
تاریخ انتشار 2009