High Spatiotemporal Resolution Dynamic Contrast-Enhanced MR Enterography in Crohn Disease Terminal Ileitis Using Continuous Golden-Angle Radial Sampling, Compressed Sensing, and Parallel Imaging.
نویسندگان
چکیده
OBJECTIVE The purpose of this article was to assess the feasibility of golden-angle radial acquisition with compress sensing reconstruction (Golden-angle RAdial Sparse Parallel [GRASP]) for acquiring high temporal resolution data for pharmacokinetic modeling while maintaining high image quality in patients with Crohn disease terminal ileitis. MATERIALS AND METHODS Fourteen patients with biopsy-proven Crohn terminal ileitis were scanned using both contrast-enhanced GRASP and Cartesian breath-hold (volume-interpolated breath-hold examination [VIBE]) acquisitions. GRASP data were reconstructed with 2.4-second temporal resolution and fitted to the generalized kinetic model using an individualized arterial input function to derive the volume transfer coefficient (K(trans)) and interstitial volume (v(e)). Reconstructions, including data from the entire GRASP acquisition and Cartesian VIBE acquisitions, were rated for image quality, artifact, and detection of typical Crohn ileitis features. RESULTS Inflamed loops of ileum had significantly higher K(trans) (3.36 ± 2.49 vs 0.86 ± 0.49 min(-1), p < 0.005) and v(e) (0.53 ± 0.15 vs 0.20 ± 0.11, p < 0.005) compared with normal bowel loops. There were no significant differences between GRASP and Cartesian VIBE for overall image quality (p = 0.180) or detection of Crohn ileitis features, although streak artifact was worse with the GRASP acquisition (p = 0.001). CONCLUSION High temporal resolution data for pharmacokinetic modeling and high spatial resolution data for morphologic image analysis can be achieved in the same acquisition using GRASP.
منابع مشابه
Golden-angle radial sparse parallel MRI: combination of compressed sensing, parallel imaging, and golden-angle radial sampling for fast and flexible dynamic volumetric MRI.
PURPOSE To develop a fast and flexible free-breathing dynamic volumetric MRI technique, iterative Golden-angle RAdial Sparse Parallel MRI (iGRASP), that combines compressed sensing, parallel imaging, and golden-angle radial sampling. METHODS Radial k-space data are acquired continuously using the golden-angle scheme and sorted into time series by grouping an arbitrary number of consecutive sp...
متن کاملDynamic Contrast-Enhanced Breast MRI using Flexible Radial Undersampling with Compressed Sensing Reconstruction
Introduction: Flexible radial imaging allows multiple image sets, each having a different spatiotemporal balance, to be retrospectively reconstructed from the same dataset [1,2]. One of the applications that may benefit from this flexibility is dynamic contrast-enhanced breast imaging, in which the optimal spatiotemporal balance for image diagnosis is unknown. Images from radial undersampling h...
متن کاملThe influence of various adaptive radial undersampling schemes on compressed-sensing L1-regularized reconstruction
Introduction Adaptive imaging allows multiple image sets, each having a different spatial-temporal balance, to be retrospectively reconstructed from the same dataset. High temporal resolution image sets from radial sampling schemes are typically undersampled, and suffer from streak artifacts that degrade image quality. It has been shown that a compressed sensing (CS) L1-penalized reconstruction...
متن کاملFree-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Kidney Using Iterative Reconstruction and Continuous Golden-Angle Radial Samplin
s, is I ts nt an eal e T T s d n), ccently introduced technique for free-breathing dynamic contrast-enhanced ren magnetic resonance imaging (MRI) applying a combination of radial k-spa sampling, parallel imaging, and compressed sensing. The technique allows re rospective reconstruction of 2 motion-suppressed sets of images from the sam acquisition: one with lower temporal resolution but improve...
متن کاملK-t Radial SPARSE-SENSE: Combination of Compressed Sensing and Parallel Imaging with Golden Angle Radial Sampling for Highly Accelerated Volumetric Dynamic MRI
Fig2. (a) Arterial and portal vein peak enhancement in two partitions (13 spokes in each time point) (b) Signal-time curve of the contrast enhancement for AO (blue) and PV (red) in partition 2 (right) Fig3. (a) Arterial and portal vein peak enhancement in two partitions (8 spokes in each time point) (b) Signal-time curve of the contrast enhancement for AO (blue) and PV (red) in partition 2 (rig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJR. American journal of roentgenology
دوره 204 6 شماره
صفحات -
تاریخ انتشار 2015