Progressive slip after removal of screw fixation in slipped capital femoral epiphysis: two case reports

نویسندگان

  • Yde Engelsma
  • Paul Morgenstern
  • Hans A Van Der Sluijs
  • Melinda M Witbreuk
چکیده

UNLABELLED INTRODUCTION In slipped capital femoral epiphysis the femoral neck displaces relative to the head due to weakening of the epiphysis. Early recognition and adequate surgical fixation is essential for a good functional outcome. The fixation should be secured until the closure of the epiphysis to prevent further slippage. A slipped capital femoral epiphysis should not be confused with a femoral neck fracture. CASE PRESENTATION Case 1 concerns a 15-year-old boy with an adequate initial screw fixation of his slipped capital femoral epiphysis. Unfortunately, it was thought that the epiphysis had healed and the screw was removed after 11 weeks. This caused new instability with a progressive slip of the femoral epiphysis and subsequently re-fixation and a subtrochanteric correction osteotomy was obligatory. Case 2 concerns a 13-year-old girl with persistent hip pain after screw fixation for slipped capital femoral epiphysis. The screw was removed as lysis was seen around the screw on the hip X-ray. This operation created a new unstable situation and the slip progressed resulting in poor hip function. A correction osteotomy with re-screw fixation was performed with a good functional result. CONCLUSION A slipped epiphysis of the hip is not considered 'healed' after a few months. Given the risk of progression of the slip the fixation material cannot be removed before closure of the growth plate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Slipped capital femoral epiphysis].

Slipped capital femoral epiphysis (SFCE) is a disorder of the hip, characterized by a displacement of the capital femoral epiphysis from the metaphysic through the femoral growth plate. The epiphysis slips posteriorly and inferiorly. SCFE occurs during puberty and metabolic and epidemiologic risk factors, such as obesity are frequently found. Most chronic slips are diagnosed late. Sagittal hip ...

متن کامل

Lateral insertion is a good prognostic factor after in situ fixation in slipped capital femoral epiphysis

BACKGROUND In situ fixation (ISF) is standard treatment for slipped capital femoral epiphysis (SCFE) to stabilize the epiphysis and to prevent further slip. The aim of this study was to clarify the incidence of slip progression after ISF and its prognostic factors. METHODS We retrospectively reviewed 53 hips in 49 consecutive SCFE patients who underwent single screw ISF and were followed unti...

متن کامل

Surgical Technique on screw removal in case of broken screw in SCFE Introduction Slipped Capital Femoral Epiphysis

We describe a case where a traumatic unstable SCFE that was initially treated with closed reduction and fixation with a single transphyseal screw went on to hardware failure with recurrence of the deformity. The complication was successfully treated with closed reduction and recannulating the fractured screw within the epiphysis and extracting it using a conical extraction screw commonly referr...

متن کامل

Bilateral epiphyseal migration following fixation for slipped capital femoral epiphyses in a hypothyroid child.

Progression of slipped capital femoral epiphysis following in situ screw fixation typically occurs through loosening of the screw in the metaphysis. Epiphyseal migration off the screw due to physeal growth is rare. We report epiphyseal migration off bilateral screws in a child undergoing thyroid replacement therapy. Patients with mild and moderate slipped capital femoral epiphysis and endocrine...

متن کامل

Biomechanical analysis of single screw fixation for slipped capital femoral epiphysis: are more threads across the physis necessary for stability?

PURPOSE To evaluate single screw fixation stability, in the treatment of slipped capital femoral epiphysis, as a function of screw thread distribution across the physis. STUDY DESIGN In vitro biomechanical study. METHODS Thirty porcine proximal femurs were sectioned through the physeal line and stabilized with a cannulated 7.3-mm stainless steel AO screw. The distal 16 mm of each screw was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012