Title of thesis: CLOSED-LOOP FLUID RESUSCITATION: INSILICO STUDY Jonathan Cary Lucas V, Master of Science, 2015 Thesis directed by: Dr. Jin-Oh Hahn Department of Mechanical Engineering This thesis validates a control-oriented model of human circulatory dynamics associated with hemorrhage and fluid resuscitation, uses this model to design a series of closed-loop controllers for fluid resuscitation, and demonstrates the viability of these controllers by examining the performance of these controllers in an established model of human cardiovascular physiology. First, a recently developed control-oriented model of hemorrhage and fluid resuscitation was validated across diverse physiological conditions using an established model of human cardiovascular physiology, by employing a system identification procedure. Second, a series of closed-loop controllers were designed based on the nominal control-oriented model, including proportional control and proportionalderivative control based on the root locus analysis, as well as observer-based optimal state feedback control based on modern control theory. Third, the performance and robustness of the designed closed-loop controllers were validated using the established model of human cardiovascular physiology. The results suggested that model-based closed-loop control may be a viable alternative to today’s manual fluid infusion practices. CLOSED-LOOP FLUID RESUSCIATION: IN-SILICO STUDY

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed-loop control of fluid therapy for treatment of hypovolemia.

Closed-loop algorithms and resuscitation systems are being developed to control IV infusion rate during early resuscitation of hypovolemia. Although several different physiologic variables have been suggested as an endpoint to guide fluid therapy, blood pressure remains the most used variable for the initial assessment of hemorrhagic shock and the treatment response to volume loading. Closed-lo...

متن کامل

Closed-loop assisted versus manual goal-directed fluid therapy during high-risk abdominal surgery: a case–control study with propensity matching

INTRODUCTION Goal-directed fluid therapy strategies have been shown to benefit moderate- to high-risk surgery patients. Despite this, these strategies are often not implemented. The aim of this study was to assess a closed-loop fluid administration system in a surgical cohort and compare the results with those for matched patients who received manual management. Our hypothesis was that the pati...

متن کامل

Evaluation of a novel closed-loop fluid-administration system based on dynamic predictors of fluid responsiveness: an in silico simulation study

INTRODUCTION Dynamic predictors of fluid responsiveness have made automated management of fluid resuscitation more practical. We present initial simulation data for a novel closed-loop fluid-management algorithm (LIR, Learning Intravenous Resuscitator). METHODS The performance of the closed-loop algorithm was tested in three phases by using a patient simulator including a pulse-pressure varia...

متن کامل

Closed-loop and decision-assist resuscitation of burn patients.

Effective resuscitation is critical in reducing mortality and morbidity rates of patients with acute burns. To this end, guidelines and formulas have been developed to define infusion rates and volume requirements during the first 48 hours postburn. Even with these standardized resuscitation guidelines, however, over- and under-resuscitation are not uncommon. Two approaches to adjust infusion r...

متن کامل

Automated closed-loop resuscitation of multiple hemorrhages: a comparison between fuzzy logic and decision table controllers in a sheep model

BACKGROUND Hemorrhagic shock is the leading cause of trauma-related death in the military setting. Definitive surgical treatment of a combat casualty can be delayed and life-saving fluid resuscitation might be necessary in the field. Therefore, improved resuscitation strategies are critically needed for prolonged field and en route care. We developed an automated closed-loop control system capa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015