Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers.
نویسندگان
چکیده
Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean±standard deviation [SD], 37.1°C to 37.36°C±0.91°C to 1.02°C). STs are 1.39°C to 1.65°C lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below 36.5°C or 37°C, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below 36.5°C or 37°C resulting in a much improved mean±SD of 37.6°C±0.64°C or 37.8°C±0.55°C, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck.
منابع مشابه
Effect of amino acid supplementation on whole-body protein turnover in Holstein steers.
We used the [15N]glycine single-dose urea end-product technique to measure whole-body protein turnover in six Holstein steers (250 +/- 18 kg). Steers were implanted with Revalor-S and continuously infused abomasally with water (4 L/d) or amino acids (AA; in 4 L/d water) in a crossover experiment (two 14-d periods). The AA infusion contained the following (g/d): lysine (5.3), methionine (3.3), t...
متن کاملPredicting net energy and protein requirements for growth of implanted and nonimplanted heifers and steers and nonimplanted bulls varying in body size.
Energy and protein retained in 50, 38, and 54 nonimplanted Holstein and Angus heifers, steers, and bulls, respectively, 17 pens (237 cattle) of beef breed implanted heifers, and 65 pens (535 cattle) of beef breed implanted steers were compared to values predicted by the 1984 National Research Council (NRC), Cornell Net Carbohydrate and Protein System (CNCPS), and the model of Oltjen et al. (OLT...
متن کاملA Temperature-Monitoring Vaginal Ring for Measuring Adherence
BACKGROUND Product adherence is a pivotal issue in the development of effective vaginal microbicides to reduce sexual transmission of HIV. To date, the six Phase III studies of vaginal gel products have relied primarily on self-reporting of adherence. Accurate and reliable methods for monitoring user adherence to microbicide-releasing vaginal rings have yet to be established. METHODS A silico...
متن کاملGrowth, feed efficiency and variation of individually fed Angus, polled Hereford and Holstein steers.
Individual growth and feed intake of 36 Angus, 27 Polled Hereford and 30 Holstein steers were determined from 365 to 560 kg live weight. One-half of the cattle in each breed were fed a diet based on high-moisture ear corn and the other one-half were fed a diet based on corn silage. Within each breed X diet group, half of the cattle were implanted with zeranol. Cattle fed the high-moisture ear c...
متن کاملAgreement between rectal and vaginal temperature measured with temperature loggers in dairy cows.
The overall objective of this study was to evaluate agreement between rectal (RT) and vaginal temperature (VT) measured with the same temperature loggers in dairy cows. Three experiments were conducted. The study began with a validation in vitro of 24 temperature loggers comparing them to a calibrated liquid-in-glass thermometer as a reference method. The association and agreement between the 2...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Asian-Australasian journal of animal sciences
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2016