An indigenously designed apparatus for measuring orthodontic force.
نویسندگان
چکیده
AIM An indigenous apparatus is designed to measure the orthodontic force delivered from elastomeric chains and compare this force with values obtained from the Instron universal testing machine. MATERIAL AND METHODS An indigenously designed apparatus is developed to evaluate forces delivered by various orthodontic auxiliaries. The apparatus consists of a flat steel platform, movable arm, and a mounted screw gauge arm. Orthodontic brackets can be attached to these arms. An electric circuit is connected, to the movable arm, which will estimate the forces exerted between brackets with elastomeric chain. The circuit is connected to the signal conditioner which will display the reading. Elastomeric chain with four links is attached to the arms. The movable arm is adjusted to create orthodontic forces and calibrated on the digital displayer. Twenty Elastomeric chains are used and forces are calibrated with the indigenously designed apparatus. The values of the force is compared with the forces calibrated with Instron universal testing machine to compare the efficacy of the indigenous apparatus. RESULTS The force values obtained from activation of elastomeric chain segments, in the Instron universal testing machine and the indigenous apparatus were in the range of 100 to 150 grams, initially at 1mm activation then, took a steep rise to 300 to 350 grams at 5mm activation and then, had a gradual increase for the remaining 5mm activation, reaching 400 to 450 grams. CONCLUSION The Indigenous apparatus can be considered efficient in measuring tensile force generated by orthodontic auxiliaries.
منابع مشابه
Effects of a newly designed apparatus on orthodontic skeletal anchorage
OBJECTIVE An appliance was designed to increase the cortical bone surface contact area of miniscrew implants (MSIs). The purpose of this in vitro study was to evaluate the effects of this appliance on the anchorage force resistance and the stability of orthodontic MSIs. MATERIALS AND METHODS A total of 48 MSIs were placed into bone specimens prepared from the ilium of bovines. Half were place...
متن کاملDigital design and fabrication of simulation model for measuring orthodontic force.
Three dimensional (3D) forces are the key factors for determining movement of teeth during orthodontic treatment. Designing precise forces and torques on tooth before treatment can result accurate tooth movements, but it is too difficult to realize. In orthodontic biomechanical systems, the periodontal tissues, including bones, teeth, and periodontal ligaments (PDL), are affected by braces, and...
متن کاملForce Relaxation Characteristics of Medium Force Orthodontic Latex Elastics: A Pilot Study
To evaluate force extension relaxation of different brands and diameters of latex elastics subjected to static tensile testing under an apparatus designed to simulate oral environments, sample sizes of 5 elastics from American Orthodontics (AO), Tp, and Morelli Orthodontics (Mo) of equivalent medium force, (3/16, 1/4, and 5/16 inch size) were tested. The forces were read after 1-, 3-, 6-, 12- a...
متن کاملDevelopment of a standardized testing system for orthodontic sliding mechanics
BACKGROUND The primary objective of this study was to develop a computer-controlled three-dimensional friction measuring system, the orthodontic friction simulator (OFS). A clinically-based in vitro experiment considering wet and dry friction for conventionally and self-ligated brackets is presented to elucidate debate surrounding sliding mechanics and illustrate capabilities of the OFS. METH...
متن کاملComparing the elastomeric behavior and force degradation pattern between different orthodontic elastomeric chains
Background and Aims: Elastomeric chains are known as a current device with the purpose of dental movement in orthodontic treatments. The aim of this study was to compare the elastomeric behavior and force degradation rate between different elastomeric chains existing in Iran in different time durations. Materials and Methods: 11 different elastomeric chains used in this study were: Class One, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical and diagnostic research : JCDR
دوره 7 11 شماره
صفحات -
تاریخ انتشار 2013