An Adaptive PMU Based Fault Detection/Location Technique for Transmission Lines—Part II: PMU Implementation and Performance Evaluation

نویسندگان

  • Joe-Air Jiang
  • Ying-Hong Lin
  • Jun-Zhe Yang
  • Chih-Wen Liu
چکیده

Part I of this paper set sets forth theory and algorithms for adaptive fault detection/location technique, which is based on Phasor Measurement Unit (PMU). This paper is Part II of this paper set. A new timing device named “Global Synchronism Clock Generator, GSCG” including its hardware and software design is described in this paper. Experimental results show that the synchronized error of rising edge between the two GSCGs clock is well within 1 ps when the clock frequency is below 2.499 MHz. The measurement results between Chung-Jeng and Chang-Te 161 kV substations of Taiwan Power company by PMU equipped with GSCG is presented and the accuracy for estimating parameters of line is verified. The new developed DFT based method (termed as Smart Discrete Fourier Transform, SDFT) and line parameter estimation algorithm are combined with PMU configuration to form the adaptive fault detector/locator system. Simulation results have shown that SDFT method can extract exact phasors in the presence of frequency deviation and harmonics. The parameter estimation algorithm can also trace exact parameters very well. The SDFT method and parameter estimation algorithm can achieve accuracies of up to 99.999% and 99.99%, respectively. The EMTP is used to simulate a 345 kV transmission line of Taipower System. Results have shown that the proposed technique yields correct results independent of fault types and is insensitive to the variation of source impedance, fault impedance, and line loading. The accuracy of fault location estimation achieved can be up to 99.9% for many simulated cases. The proposed technique will be very suitable for implementation in an integrated digital protection and control system for transmission substations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

الگوریتم جامعی برای مکان یابی خطا در خطوط انتقال دو مداره و چند پایانه ای (بیش از سه پایانه) مبتنی بر داده های PMU

A new PMU-based fault detection/location algorithm for multi-terminal transmission lines is proposed in this paper, which works on the basis of synchronized voltage and current phasors received from PMUs installed in various terminals. The Clark transform (for transposed transmission lines), Eigen-values and eigenvectors theory (for un-transposed ones) are used to decouple 3-phase differential ...

متن کامل

Fault Location on Compensated Transmission Lines without Current Measurement

This paper presents a novel fault location method for series compensated transmission lines. It is established based on synchronized voltages sampling and Thevenin impedance from both ends of series compensated transmission line. The method is based on the use of phasor measurement units (PMU) technology which is aimed to be independent of current measurements, fault type, fault resistance, fau...

متن کامل

A Voltage Phasor Based Fault Classification Method for PMU Only State Estimator Output

This paper presents a fault classification method for transmission lines based on voltage phasors using classification and regression trees (CART). The proposed method is intended to aid system operators in understanding the outputs of a PMU only state estimator. Faults are classified into four categories when the estimator is positive sequence and into ten categories when the estimator is thre...

متن کامل

A Novel Fault Detection and Classification Approach in Transmission Lines Based on Statistical Patterns

Symmetrical nature of mean of electrical signals during normal operating conditions is used in the fault detection task for dependable, robust, and simple fault detector implementation is presented in this work. Every fourth cycle of the instantaneous current signal, the mean is computed and carried into the next cycle to discover nonlinearities in the signal. A fault detection task is complete...

متن کامل

An Electrical Structure-Based Approach to PMU Placement in the Electric Power Grid

The phasor measurement unit (PMU) placement problem is revisited by taking into account a stronger characterization of the electrical connectedness between various buses in the grid. To facilitate this study, the placement problem is approached from the perspective of the electrical structure which, unlike previous work on PMU placement, accounts for the sensitivity between power injections and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001