Detection of Noble Gas Scintillation Light with Large Area Avalanche Photodiodes (LAAPDs)

نویسندگان

  • R. Chandrasekharan M. Messina
  • A. Rubbia
چکیده

Large Area Avalanche Photodiodes (LAAPDs) were used for a series of systematic measurements of the scintillation light in Ar, Kr, and Xe gas. Absolute quantum efficiencies are derived. Values for Xe and Kr are consistent with those given by the manufacturer. For the first time we show that argon scintillation (128 nm) can be detected at a quantum efficiency above 40%. Low-pressure argon gas is shown to emit significant amounts of non-UV radiation. The average energy expenditure for the creation of non-UV photons in argon gas at this pressure is measured to be below 378 eV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-linear behaviour of large-area avalanche photodiodes

The characterisation of photodiodes used as photosensors requires a determination of the number of electron–hole pairs produced by scintillation light. One method involves comparing signals produced by X-ray absorptions occurring directly in the avalanche photodiode with the light signals. When the light is derived from light-emitting diodes in the 400–600 nm range, significant non-linear behav...

متن کامل

Application of large-area avalanche photodiodes to energy-dispersive x-ray fluorescence analysis

The performance of several large-area avalanche photodiodes (LAAPDs) for application to x-ray spectrometry at room temperature was investigated. Optimum detector performance was obtained for gains of about 50–70. Good energy linearity of the LAAPDs’ response to x-rays was observed up to energies of about 25 keV. For this energy range the space charge effects are negligible for gains below 100–1...

متن کامل

Design of a High-Resolution and High-Sensitivity Scintillation Crystal Array for PET With Nearly Complete Light Collection

Spatial resolution improvements in positron emission tomography (PET) can be achieved by developing detector arrays with finer resolution elements. To maintain high sensitivity and image quality, the challenge is to develop a finely pixellated scintillation crystal array with both high detection efficiency and high light collection. High detection efficiency means the crystals must be relativel...

متن کامل

High-pressure Helium-3 Scintillation Position-sensitive Detector of Thermal Neutrons

The objective of this study is to demonstrate the feasibility of constructing a compact neutron detector that is sensitive to thermal and epithermal neutrons and has high rejection efficiency relative to gamma-ray background. A two-channel high-pressure He scintillation detector is considered for the detection of neutrons in coincidence mode. The detector consists of two large avalanche photodi...

متن کامل

The Development of Gaseous Detectors with Solid Photocathodes for Low Temperature

There are several applications and fundamental research areas which require the detection of VUV light at cryogenic temperatures. For these applications we have developed and successfully tested special designs of gaseous detectors with solid photocathodes able to operate at low temperatures: sealed gaseous detectors with MgF2 windows and windowless detectors. We have experimentally demonstrate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004