Validation of an automated method to quantify stress-induced ischemia and infarction in rest-stress myocardial perfusion SPECT.

نویسندگان

  • Helen Fransson
  • Michael Ljungberg
  • Marcus Carlsson
  • Henrik Engblom
  • Håkan Arheden
  • Einar Heiberg
چکیده

BACKGROUND Myocardial perfusion SPECT (MPS) is one of the frequently used methods for quantification of perfusion defects in patients with known or suspected coronary artery disease. This article describes open access software for automated quantification in MPS of stress-induced ischemia and infarction and provides phantom and in vivo validation. METHODS AND RESULTS A total of 492 patients with known or suspected coronary artery disease underwent both stress and rest MPS. The proposed perfusion analysis algorithm (Segment) was trained in 140 patients and validated in the remaining 352 patients using visual scoring in MPS by an expert reader as reference standard. Furthermore, validation was performed with simulated perfusion defects in an anthropomorphic computer model. Total perfusion deficit (TPD, range 0-100), including both extent and severity of the perfusion defect, was used as the global measurement of the perfusion defects. Mean bias ± SD between TPD by Segment and the simulated TPD was 3.6 ± 3.8 (R(2) = 0.92). Mean bias ± SD between TPD by Segment and the visual scoring in the patients was 1.2 ± 2.9 (R (2)= 0.64) for stress-induced ischemia and -0.3 ± 3.1 (R(2) = 0.86) for infarction. CONCLUSION The proposed algorithm can detect and quantify perfusion defects in MPS with good agreement to expert readers and to simulated values in a computer phantom.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 2014