Saline aerosol bolus dispersion. II. The effect of conductive airway alteration.

نویسندگان

  • S Verbanck
  • D Schuermans
  • M Paiva
  • W Vincken
چکیده

In a companion study (Verbanck S, Schuermans D, Vincken W, and Paiva M, J Appl Physiol 90: 1754-1762, 2001), we investigated whether saline aerosol bolus tests could also be used to detect proximal, as opposed to peripheral, airway alterations. We studied 10 never-smokers before and after histamine challenge, obtaining, for various volumetric lung depths (VLD), saline bolus-derived indexes computed by discarding aerosol concentrations below either 50% of the exhaled bolus maximum (half-width, H) or below cutoffs ranging from 5 to 25% (standard deviation, sigma(5%)-sigma(25%)) and skew (sk(5)-sk(25%)). Multiple-breath N(2) washout-derived indexes of conductive (S(cond)) and acinar (S(acin)) ventilation inhomogeneity were also determined. After histamine, S(cond) significantly increased (P = 0.008) whereas S(acin) remained unaffected, indicating purely conductive airway alteration. Consistent with this observation, sk(5%) (or sk(25%)) was increased to the same extent at all VLD, and sigma(5%) was increased preferentially at low VLD. By contrast, H and sigma(25%) displayed preferential increases at high VLD, a pattern similar to that induced by peripheral alterations. The present work shows that proximal airway alteration can be reliably identified by saline bolus tests only if these include measurements at low and high VLD and if bolus dispersion is quantified as a standard deviation with a low cutoff.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Saline aerosol bolus dispersion. I. The effect of acinar airway alteration.

We explored the possibility of using a saline aerosol for bolus dispersion measurements to detect peripheral airway alterations in smokers. Indexes of ventilation inhomogeneity in conductive (S(cond)) and acinar (S(acin)) lung zones, as derived from the multiple-breath N(2) washout (Verbanck S, Schuermans D, Van Muylem A, Noppen M, Paiva M, and Vincken W, J Appl Physiol 83: 1807-1816, 1997), we...

متن کامل

Effect of ventilation distribution on aerosol bolus dispersion and recovery.

It has been speculated that convective ventilatory inhomogeneities are an important factor influencing aerosol bolus behavior in the compromised lung. Multiple-breath 133Xe washout (MBWXe) is a commonly accepted test of ventilation distribution. By comparing aerosol bolus parameters to MBWXe in 9 healthy subjects and 14 cystic fibrosis patients with mild-to-moderate airway obstruction, we have ...

متن کامل

Contribution of upper airway geometry to convective mixing.

We investigated the axial dispersive effect of the upper airway structure (comprising mouth cavity, oropharynx, and trachea) on a traversing aerosol bolus. This was done by means of aerosol bolus experiments on a hollow cast of a realistic upper airway model (UAM) and three-dimensional computational fluid dynamics (CFD) simulations in the same UAM geometry. The experiments showed that 50-ml bol...

متن کامل

Aerosol bolus dispersion and effective airway diameters in mildly asthmatic children.

The contribution of aerosol techniques, the estimation of aerosol bolus dispersion and effective airway dimensions, to the clinical diagnosis of paediatric asthma was studied. In 47 children, aged 11 +/- 2 yrs, with mild asthma (forced expiratory volume in one second (FEV1) 83 +/- 9% of forced vital capacity (FVC)) effective airway diameters were derived from the recovery of inhaled 1 micron se...

متن کامل

Aerosol bolus dispersion in acinar airways--influence of gravity and airway asymmetry.

The aerosol bolus technique can be used to estimate the degree of convective mixing in the lung; however, contributions of different lung compartments to measured dispersion cannot be differentiated unambiguously. To estimate dispersion in the distal lung, we studied the effect of gravity and airway asymmetry on the dispersion of 1 μm-diameter particle boluses in three-dimensional computational...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 90 5  شماره 

صفحات  -

تاریخ انتشار 2001