99mTc-bicisate and 99mTc-HMPAO SPECT imaging in early spontaneous reperfusion of cerebral embolism.

نویسندگان

  • K Ogasawara
  • K Mizoi
  • S Fujiwara
  • T Yoshimoto
چکیده

Two patients with a cerebral embolism were evaluated by using both 99mTc-ethyl cysteinate dimer (ECD, or Bicisate) and 99mTc-hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). In one patient, 99mTc-ECD SPECT images revealed hypoactivity in a reflow hyperemic area where an infarct was seen later on CT scans. In another patient, a reperfused area showed hyperactivity on 99mTc-ECD SPECT without any abnormality on follow-up CT. 99mTc-ECD represents a potential agent with which to evaluate cerebral tissue viability in early reperfusion after ischemia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Brain single-photon emission CT studies using 99mTc-HMPAO and 99mTc-ECD early after recanalization by local intraarterial thrombolysis in patients with acute embolic middle cerebral artery occlusion.

BACKGROUND AND PURPOSE The brain distribution of 9mTc-hexamethylpropyleneamine oxime (HMPAO) correlates with regional brain perfusion, whereas 99mTc-ethyl cysteinate dimer (ECD) reflects not only perfusion but also the metabolic status of brain tissue. We compared 99mTc-ECD single-photon emission CT (SPECT) with 99mTc-HMPAO SPECT early after recanalization by local intraarterial thrombolysis (L...

متن کامل

The diagnostic difference between 18F- FDG PET and 99mTc-HMPAO SPECT perfusion imaging in assessment of Alzheimer's disease

Introduction:Brain imaging with F-18 fluorodeoxyglucose (18F-FDG) positron ‎emission tomography or Tc-99m hexamethylpropyleneamine oxime (‎99mTc-HMPAO) SPECT is widely used for the evaluation of Alzheimer's ‎dementia (AD); we aim to assess superiority of one method over the ‎other. Methods: Twenty four patients with clinical diagnosi...

متن کامل

Comparative study of 99mTc-ECD and 99mTc-HMPAO for peri-ictal SPECT: qualitative and quantitative analysis.

OBJECTIVES Most studies that clinically validated peri-ictal SPECT in intractable partial epilepsy had used technetium-99m-hexamethylpropylene amine oxime (99mTc-HMPAO or 99mTc-exametazime) as the radiopharmaceutical. Because of some theoretical advantages, technetium-99m-ethyl cysteinate diethylester (99mTc-ECD or 99mTc-bicisate) is increasingly being used instead. This study compares unstabil...

متن کامل

Improved detection of cerebral hypoperfusion with internal carotid balloon test occlusion and 99mTc-HMPAO cerebral perfusion SPECT imaging.

A new method that employs a cerebral perfusion imaging agent, 99mTc-HMPAO, is described for identifying those patients who clinically pass an internal carotid artery balloon test occlusion but who then may develop a cerebral infarction after permanent occlusion. Test balloon occlusion of the internal carotid artery was performed in 17 patients, and 99mTc-HMPAO was injected intravenously while t...

متن کامل

Nano Liposomes labeled with 99mTc-HMPAO, A Novel Agent for Blood Pool Imaging

In-vitro labeling of RBC with 99mTc is an intricate procedure and there is always a need foran alternate blood pool imaging agent. The aim of this study was to prepare an effective nanosized liposome (NLs) similar to human RBC for blood pool scintigraphy. This study formulatesPEG-NLs and non-PEG-NLs using film method plus high pressure homogenization technique.Biodistribution studies were perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 1999