Sensitivity Encoded Proton Echo Planar Spectroscopic Imaging (SENSE-PEPSI) on Human Brain Using a Large-N Coil Array

نویسندگان

  • S-Y. Tsai
  • S. Posse
  • L. L. Wald
  • C-W. Ko
  • H-W. Chung
  • F-H. Lin
چکیده

S-Y. Tsai, S. Posse, L. L. Wald, C-W. Ko, H-W. Chung, F-H. Lin Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Chalestown, MA, United States, Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan, MIND Institute, 801 University Blvd SE, Suite 200, Albuquerque, NM, United States, Department of Psychiatry and Department of Electrical & Computer Engineering, University of New Mexico, Albuquerque, NM, United States, Department of Computer Science and Engineering, National Sun Yat-sen University, Kaohsiung, Taiwan

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Encoded Proton Echo Planar Spectroscopic Imaging (PEPSI) in Human Brain at 7 Tesla

choline, glutamate and inositol (32x32 matrix) with 2-fold SENSE acceleration. Fig.3 Fully sampled PEPSI maps of non-suppressed water (64x64 matrix) and metabolite maps of NAA, creatine, choline, glutamate and inositol (32x32 matrix), acquired in 8.5 min with 0.63 cc voxel size. Fig.1 Non-water-suppressed PEPSI maps on phantom at 7 T show good reconstruction performance for up to 4-fold acceler...

متن کامل

High Spatial Resolution Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) in Human Brain at 3 Tesla using 32-Channel RF Coil Array

15 mm PEPSI slice) and metabolic images of mI, Cho, Cr+PCr, Glu+Gln, NAA+NAAG and macromolecules at 0.9 ppm (MM09) measured with 0.25 cc spatial resolution, (left) before and (right) after partial volume and relaxation correction. Cho, Cr+PCr and Glu+Gln maps show strong GM/WM contrast and considerable anatomical detail, including sulcal structure (see red and yellow arrows). Fig.1:Selected cen...

متن کامل

Accelerated proton echo planar spectroscopic imaging (PEPSI) using GRAPPA with a 32-channel phased-array coil.

Parallel imaging has been demonstrated to reduce the encoding time of MR spectroscopic imaging (MRSI). Here we investigate up to 5-fold acceleration of 2D proton echo planar spectroscopic imaging (PEPSI) at 3T using generalized autocalibrating partial parallel acquisition (GRAPPA) with a 32-channel coil array, 1.5 cm(3) voxel size, TR/TE of 15/2000 ms, and 2.1 Hz spectral resolution. Compared t...

متن کامل

GRAPPA Reconstruction of Sensitivity Encoded 2D and 3D Proton Echo Planar Spectroscopic Imaging (PEPSI) with SNR Adaptive Recalibrating

M. Rueckert, R. Otazo, S. Posse MIND Institute, Albuquerque, New Mexico, United States, Dept. of Physics and Astronomy, University of New Mexico, Albuquerque, New Mexico, United States, Dept. of Electrical and Computer Engineering, University of New Mexico, Albuquerque, New Mexico, United States, Dept. of Psychiatry, University of New Mexico School of Medicine, Albuquerque, New Mexico, United S...

متن کامل

Single-shot magnetic resonance spectroscopic imaging with partial parallel imaging.

A magnetic resonance spectroscopic imaging (MRSI) pulse sequence based on proton-echo-planar-spectroscopic-imaging (PEPSI) is introduced that measures two-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005