Clinical Outcomes Assessment of Three Similar Hip Arthroplasty Bearing Surfaces
نویسندگان
چکیده
This report examines the clinical performance of three very similar total hip arthroplasty designs with distinctly different bearing surfaces used over the course 10-17 years. Clinical outcomes assessments for each group are compared in the context of varying implant related costs related to the latest technology at the time of surgery. Eighty-one surgeries were studied and differ by bearing surface. In this study, 36 hips are ceramic on polyethylene, 27 are metal on polyethylene and 18 are metal on metal. All polyethylene components are nonhighly cross-linked. The ceramic on polyethylene group has younger patients, on average, and higher percentage of patients with significant polyethylene wear. These groups have an average follow-up time of 8.6 years when assessing functional hip scores, thigh pain, groin pain, revision surgeries and radiographic osteolysis. The implant purchasing cost at the time of surgery was assessed to determine if a correlation exists between outcomes and the more technologically advanced implants use at the time of surgery. Based on midterm clinical outcome assessment, no correlation between initial hospital cost and clinical outcomes of one bearing surface over another can be found.
منابع مشابه
Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...
متن کاملA Single Femoral Component for All Total Hip Replacements Performed by a Trust? Does This Affect Early Clinical and Radiological Outcomes?
Background: Hospitals may be under pressure to implement cost saving strategies regarding prosthesis choice. Thismay involve the use of components which are not the first preference of individual surgeons, or those they have littleexperience with. We aim to examine the effect of standardizing the type of femoral stem used in a single trust, anddetermine whether this is safe practice, particular...
متن کاملStudy of the Polycarbonate-Urethane/Metal Contact in Different Positions during Gait Cycle
Nowadays, a growing number of young and more active patients receive hip replacement. More strenuous activities in such patients involve higher friction and wear rates, with friction on the bearing surface being crucial to ensure arthroplasty survival in the long term. Over the last years, the polycarbonate-urethane has offered a feasible alternative to conventional bearings. A finite element m...
متن کاملA critical appraisal of the evidence regarding the choice of common bearing couples available for total hip arthroplasty.
There are a variety of materials used in bearing components in total hip replacement (THR). Metal-on-polyethylene replacements, having undergone small technical refinements in design over the last 30- 40 years, give, according to the Scandinavian hip register, very good 10-year outcomes. However, aseptic loosening, caused to a great extent by adverse biological local reactions, induced by wear ...
متن کاملErratum for Ceramic-on-Ceramic Versus Ceramic-on-Polyethylene Bearing Surfaces in Total Hip Arthroplasty.
The choice between ceramic-on-ceramic (COC) and ceramic-on-polyethylene (COP) in primary total hip arthroplasty (THA) remains controversial. The purpose of this study was to evaluate the reliability and durability of COC vs COP bearing surfaces in THA. Based on published randomized, controlled trials (RCTs) identified in PubMed, Embase, and the Cochrane Central Register of Controlled Trials, th...
متن کامل