Refractive outcome in eyes with retinopathy of prematurity treated with cryotherapy or diode laser: 3 year follow up.
نویسندگان
چکیده
AIMS To compare the refractive error 1 to 3 years after cryotherapy or diode laser treatment for threshold retinopathy of prematurity. METHODS Twenty six infants treated with diode laser and 17 infants treated with cryotherapy underwent cycloplegic refraction during follow up. RESULTS After 3 years of follow up, 94.1% of patients had myopia (right eye if bilateral) following cryotherapy and 45.5% of patients had myopia following diode laser treatment. The difference between the two proportions was 48.7% (95% confidence interval 17.8 to 80.1, p = 0.004). In the cryotherapy group 55% of patients were highly myopic (> -6.00 dioptres) while in the laser group there were no high myopes. CONCLUSIONS In the diode laser group there were significantly fewer myopes than in the cryotherapy group up to 3 years after the procedure. There was no trend towards increasing myopia in the laser treated group and the refraction in these eyes stabilised after 1 year. In the cryotherapy group there was a significant increase in the degree of myopia between year 1 and year 3 of follow up (p = 0.02). Diode laser treatment is thought to be as effective as cryotherapy, and has the added benefit of reducing myopia, in the treatment of ROP.
منابع مشابه
Longer-term visual outcome of eyes with retinopathy of prematurity treated with cryotherapy or diode laser.
AIMS Visual outcome of 66 eyes in 37 patients who had undergone treatment with either cryotherapy or diode laser for threshold retinopathy of prematurity was assessed. METHODS 17 patients, representing 30 eyes treated with cryotherapy, were examined at between 56 and 98 months corrected age (median 68 months). 20 patients representing 36 eyes treated with diode laser, were examined at between...
متن کاملDiode laser ablation for threshold retinopathy of prematurity: short-term structural outcome.
OBJECTIVE To describe short-term structural outcomes and associated ocular complications in premature infants treated with diode laser ablation for retinopathy of prematurity. METHODS The records of all infants who were diagnosed as having threshold retinopathy of prematurity and treated with diode laser therapy at our hospital from January 1, 1992, through December 31, 1996, were retrospecti...
متن کاملDiode laser treatment for retinopathy of prematurity: structural and functional outcome.
AIMS The anatomical and functional outcome of 13 babies with retinopathy of prematurity (ROP) treated with binocular indirect ophthalmoscope diode laser photocoagulation was assessed. METHODS Thirteen babies (25 eyes) at median postmenstrual age (PMA) 25.5 weeks and median birth weight 725 g were treated with binocular indirect ophthalmoscope (BIO) diode laser photocoagulation when threshold ...
متن کاملComparison of treatment results for retinopathy of prematurity by diode laser photocoagulation and cryotherapy – four years of observation
Background: The aim of the study was to compare functional and structural outcomes of treatment for retinopathy of prematurity with diode laser photocoagulation and cryotherapy. Materials and methods: We examined 111 children aged 4 years, treated for retinopathy of prematurity by transpupillary diode laser photocoagulation or cryotherapy. Both functional (visual acuity, orthoptic status) and s...
متن کاملA comparison of laser photocoagulation with trans-scleral cryotherapy in the treatment of threshold retinopathy of prematurity.
OBJECTIVE The goal of this study was to determine whether there was a significant difference between the visual outcomes of eyes with threshold retinopathy of prematurity (ROP) treated with trans-scleral cryotherapy compared to those treated with laser photocoagulation. DESIGN Extended follow-up study of a prospective, randomized clinical trial. PARTICIPANTS Fifty-two patients with bilatera...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 80 11 شماره
صفحات -
تاریخ انتشار 1996