Using miniature sensor coils for simultaneous measurement of orientation and position of small, fast-moving animals.

نویسندگان

  • C Schilstra
  • J H van Hateren
چکیده

A system is described that measures, with a sampling frequency of 1 kHz, the orientation and position of a blowfly (Calliphora vicina) flying in a volume of 0.4 x 0.4 x 0.4 m3. Orientation is measured with a typical accuracy of 0.5 degrees, and position with a typical accuracy of 1 mm. This is accomplished by producing a time-varying magnetic field with three orthogonal pairs of field coils, driven sinusoidally at frequencies of 50, 68, and 86 kHz, respectively. Each pair induces a voltage at the corresponding frequency in each of three miniature orthogonal sensor coils mounted on the animal. The sensor coils are connected via thin (12-microm) wires to a set of nine lock-in amplifiers, each locking to one of the three field frequencies. Two of the pairs of field coils produce approximately homogeneous magnetic fields, which are necessary for reconstructing the orientation of the animal. The third pair produces a gradient field, which is necessary for reconstructing the position of the animal. Both sensor coils and leads are light enough (0.8-1.6 mg for three sensor coils of 40-80 windings, and 6.7 mg/m for the leads, causing a maximal load of approximately 5.7 mg) not to hinder normal flight of the animal (typical weight 80 mg). In general, the system can be used for high-speed recordings of head, eye or limb movements, where a wire connection is possible, but the mechanical load on the moving parts needs to be very small.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser-Doppler-Distance-Sensor using phase evaluation for position, shape andvibration measurements

In this article we present a novel optical sensor allowing simultaneous measurements of axial position and tangential velocity of moving solid state objects. An extended laser Doppler velocimeter setup is used where two interference fringe systems are superposed slightly tilted. The axial position of moving solid state surfaces is determined via a phase evaluation. The phase laser Doppler dista...

متن کامل

Calculation of One-dimensional Forward Modelling of Helicopter-borne Electromagnetic Data and a Sensitivity Matrix Using Fast Hankel Transforms

The helicopter-borne electromagnetic (HEM) frequency-domain exploration method is an airborne electromagnetic (AEM) technique that is widely used for vast and rough areas for resistivity imaging. The vast amount of digitized data flowing from the HEM method requires an efficient and accurate inversion algorithm. Generally, the inverse modelling of HEM data in the first step requires a precise a...

متن کامل

Improvement of position measurement for 6R robot using magnetic encoder AS5045

Recording the variation of joint angles as a feedback to the control unit is frequent in articulated arms. In this paper, magnetic sensor AS5045, which is a contactless encoder, is employed to measure joint angles of 6R robot and the performance of that is examined. The sensor has a low volume, two digital outputs and provides a high resolution measurement for users; furthermore its zero positi...

متن کامل

Detection of napropamide by microwave resonator sensor using carbon nanotube – polypyrrole- chitosan layer

This paper presents the design and fabrication of proximity coupled feed disk resonator coated with Multi Walled Carbon Nanotubes (MWCNTs) and Polypyrrole-Chitosan (PPy-CHI) layers as a napropamide sensor. Computer Simulation Technology (CST) microwave studio was used to obtain the best design of disk resonator and feed line position in 5 GHz resonant frequency. Also, MWCNTs - PPy-CHI layers we...

متن کامل

Tip sensor probe for changing refractive index measurement in small volumes

In this paper, a tapered tip optical fiber probe sensor for localized refractive index (RI) measurements is presented. This sensor’s interaction with analytes is confined to a few micro-meters which makes it a promising candidate for in-vivo or even intra-cellular RI monitoring. This tapered tip was simply fabricated by etching optical fiber with hydrofluoric acid to a conic shape with a sub-m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 83 2  شماره 

صفحات  -

تاریخ انتشار 1998