PURPOSE The aim of this study was to systematically review the evidence for periapical implant lesion, which makes a patient more susceptible to the periapical lesion, frequency, symptoms, signs (including radiological findings) and possible treatment options. MATERIAL AND METHODS A systematic literature review and analysis of publications included in PubMed, Embase and Cochrane; articles published until March 2016; with a populations, exposures and outcomes (PEO) search strategy was performed, focused on the issue: "In patients with periapical lesion to the implant during the osseointegration, what symptoms, signs, and changes in complementary examination manifested, for according to that stage, be intervened with the appropriate approach?". The set criteria for inclusion were peer-reviewed articles. RESULTS From a total of 212 papers identified, 36 studies were included in this systematic review, with 15461 implants evaluated and 183 periapical implant lesions. Which 8 papers included more than 5 cases and 28 included equal or less than 5 cases. Analysis of the papers revealed that periapical implant lesion is classified according to evolution stages into acute (non-suppurated and suppurated) and subacute (or suppurated-fistulized). In the acute stage and in the subacute if there is no loss of implant stability, the correct treatment approach is implant periapical surgery. In the subacute stage associated with implant mobility the implant must be removed. CONCLUSIONS Evidence on the subject is very limited, there are few studies with small sample, without homogeneity of criteria for diagnosing the disease and without design of scientific evidence. Currently etiology lacks consensus. The early diagnosis of periapical implant periapical lesions during the osseointegration phase and early treatment, will lead to a higher survival rate of implants treated, hence preventing the need for implant extraction.
منابع مشابه
Management of the implant periapical lesion: a case report.
The implant periapical lesion (IPL), a possible cause for implant failure, may occur from the presence of pre-existing microbial pathology such as endodontic/periodontal lesions. This case report presents a case history related to IPL, which was caused by a pre-existing endodontic lesion. In addition, other possible causes such as surgical trauma and the management strategies of IPL are suggest...
متن کاملImmediate implants placed in fresh sockets associated to periapical infectious processes. A systematic review
OBJECTIVES The development of treated implant surfaces, added to the increase of the aesthetic requirements by the patients has led to a change in the treatment protocols as well as the development of techniques such as the one-fase implants and the immediate prosthetic loading. One of the usual contraindications of the implant treatment is the presence of periapical disease associated to the t...
متن کاملDiagnosis and treatment of a large periapical implant lesion associated with adjacent natural tooth: a case report.
A possible cause for dental implant failure is the periapical implant lesion (PIL). In this case report we describe an apical periodontitis on a tooth adjacent to a dental implant that may have communicated with the apical region of the dental implant, and causing retrograde peri-implantitis. To our knowledge this is the first report demonstrating the concomitant successful treatment of the per...
متن کاملImplant periapical lesion-literature review
The etiologies and mechanisms of implant failure are multifactorial. Implant periapical lesion (IPL) is one possible cause of implant failure. IPL is an infectious-inflammatory alterations surrounding an implant apex. The diagnosis is based on the clinical manifestations and radiological findings, where a radiolucent lesion can be seen in the periapical area. It is apparent that IPL has a multi...
متن کاملRetrospective study of marginal bone change in 1 year loading of INNO® dental implant
Introduction: The marginal bone change of 1 year loading was evaluated in the non-microthread collar and platform switching structured INNO® dental implant of which the surface is treated with the RBM sandblasting, hyper-thermal acid etching and alkali solution cleaning process for hydrophilic macroand micro-porosity. Material and Methods: A total of 144 implants were placed in the healed ridge...