Rapid full-brain fMRI with an accelerated multi shot 3D EPI sequence using both UNFOLD and GRAPPA.

نویسندگان

  • Onur Afacan
  • W Scott Hoge
  • Firdaus Janoos
  • Dana H Brooks
  • Istvan A Morocz
چکیده

The desire to understand complex mental processes using functional MRI drives development of imaging techniques that scan the whole human brain at a high spatial and temporal resolution. In this work, an accelerated multishot three-dimensional echo-planar imaging sequence is proposed to increase the temporal resolution of these studies. A combination of two modern acceleration techniques, UNFOLD and GRAPPA is used in the secondary phase encoding direction to reduce the scan time effectively. The sequence (repetition time of 1.02 s) was compared with standard two-dimensional echo-planar imaging (3 s) and multishot three-dimensional echo-planar imaging (3 s) sequences with both block design and event-related functional MRI paradigms. With the same experimental setup and imaging time, the temporal resolution improvement with our sequence yields similar activation regions in the block design functional MRI paradigm with slightly increased t-scores. Moreover, additional information on the timing of rapid dynamic changes was extracted from accelerated images for the case of the event related complex mental paradigm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid full-brain fMRI with multi-shot 3D EPI accelerated with UNFOLD and GRAPPA

Introduction: Brain responses to cognitive stimuli will result in rapid dynamic BOLD signal modulations. Therefore, images acquired with high temporal resolution and full brain coverage are preferable for fMRI studies. A cascade of brain signal changes is typically observed in complex mental exercises where neural recruitment occurs in both parallel and serial fashion. Currently multi-slice sin...

متن کامل

A method to increase temporal resolution in 3D-EPI fMRI using UNFOLD

Introduction: An fMRI study is ideally acquired at a high temporal resolution and with full brain coverage at each scan time point. This prerequisite is especially true in view of the rapid dynamic BOLD signal changes expected when cognitive tasks are studied. A cascade like brain recruitment is typically observed in complex mental exercises where neural recruitment occurs in both parallel and ...

متن کامل

A Multi-Resolution Comparison of Single-Shot EPI, 3DFFE and PRESTO for fMRI at 7T

INTRODUCTION Single-shot Echo-Planar Imaging (EPI) is the sequence most commonly used for fMRI experiments. At high field, e.g. 7T, magnetic field inhomogeneities cause spins to become out of phase quickly, and distortion and signal dropout become severe [1]. Consequently, single-shot EPI fMRI suffers technical limitations at high field. Here we consider two alternatives to EPI for high field f...

متن کامل

K-space undersampling strategies for functional and cardiac MRI: achieving rapid acquisition while maintaining image quality

Northeastern University Department of Electrical and Computer Engineering Doctor of Philosophy in Electrical Engineering K-space undersampling strategies for functional and cardiac MRI: Achieving rapid acquisition while maintaining image quality by Onur Afacan Scan time is the limiting factor in many magnetic resonance imaging applications. One approach to reduce the scan time is undersampling ...

متن کامل

Event-related Functional Mri at High Spatial and Temporal Resolution Using Unfold

Introduction High temporal resolution is important to detect transient BOLD signal modulations in event-related functional MRI (fMRI) [1]. If spatial coverage is required, a major challenge for high resolution fMRI is limited temporal resolution. The UNFOLD method [2] to increase image acquisition speed has recently been applied to high resolution fMRI using a 3D-spiral sequence [3]. The presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 67 5  شماره 

صفحات  -

تاریخ انتشار 2012