چکیده

BACKGROUND AND AIMS Real-time shear wave elastography (2D-SWE) is a two-dimensional transient elastography and a competitor as a biomarker of liver fibrosis in comparison with the standard reference transient elastography by M probe (TE-M). The aims were to compare several criteria of applicability, and to assess inflammation and steatosis impact on elasticity values, two unmet needs. METHODS We took FibroTest as the fibrosis reference and ActiTest and SteatoTest as quantitative estimates of inflammation and steatosis. After standardization of estimates, analyses used curve fitting, quantitative Lin concordance coefficient [LCC], and multivariate logistic regression. RESULTS A total of 2,251 consecutive patients were included. We validated the predetermined 0.2 kPa cut-off as a too low minimal elasticity value identifying not-reliable 2D-SWE results (LCC with FibroTest = 0.0281[-0.119;0.175]. Other criteria, elasticity CV, body mass index and depth of measures were not sufficiently discriminant. The applicability of 2D-SWE (95%CI) 89.6%(88.2-90.8), was significantly higher than that of TE, 85.6%(84.0-87.0; P<0.0001). In patients with non-advanced fibrosis (METAVIR F0F1F2), elasticity values estimated by 2D-SWE was less impacted by inflammation and steatosis than elasticity value estimated by TE-M: LCC (95%CI) 0.039 (0.021;0.058) vs 0.090 (0.068;0.112;P<0.01) and 0.105 (0.068;0.141) vs 0.192 (0.153;0.230; P<0.01) respectively. The three analyses methods gave similar results. CONCLUSIONS Elasticity results including very low minimal signal in the region of interest should be considered not reliable. 2D-SWE had a higher applicability than TE, the reference elastography, with less impact of inflammation and steatosis especially in patients with non-advanced fibrosis, as presumed by blood tests. TRIAL REGISTRATION ClinicalTrials.gov NCT01927133.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liver elastography - an update.

Liver fibrosis evaluation is very important for treatment and prognosis in patients with chronic liver disease. The "gold-standard" method for liver fibrosis assessment is still considered to be the liver biopsy, but in the last years non-invasive methods have increasingly been used, especially ultrasound based elastographic ones. The oldest and the only validated elastographic method for non-i...

متن کامل

Principles and clinical application of ultrasound elastography for diffuse liver disease

Accurate assessment of the degree of liver fibrosis is important for estimating prognosis and deciding on an appropriate course of treatment for cases of chronic liver disease (CLD) with various etiologies. Because of the inherent limitations of liver biopsy, there is a great need for non-invasive and reliable tests that accurately estimate the degree of liver fibrosis. Ultrasound (US) elastogr...

متن کامل

Performance of unidimensional transient elastography in staging non-alcoholic steatohepatitis.

BACKGROUND/AIMS Transient elastography (TE) is a noninvasive method for predicting liver fibrosis, mainly validated in patients with viral hepatitis. Information is still limited concerning its performance in non-alcoholic steatohepatitis (NASH) patients. We aimed to assess the value of TE in the prediction of fibrosis stage in NASH as well as the factors determining the discordance between the...

متن کامل

Assessing the consistency of liver fibrosis results obtained through biopsy and transient elastography in patients suffering from chronic hepatitis C

Until recently, core-needle liver biopsy was used as the gold standard in chronic hepatitis C diagnostics. Information on the inflammatory activity grade and the staging of liver fibrosis or steatosis, obtained through biopsy, constituted an indispensable element in the process of determining patients' eligibility for antiviral treatment. The histological profile of the samples examined was dec...

متن کامل

Non-invasive Diagnosis of Liver Clinical Condition by Real-time Tissue Elastography and Shear Wave Measurement : Get More Accessible by One Probe

It is ver y important to understand the stage of liver fibrosis and the level of inflammation both in a treatment plan setting and for predicting the prognosis of viral and other diffuse liver diseases. Liver biopsy is considered as the gold standard but it has problems relating to its invasiveness (pain and bleeding) and the possibility of bias due to sampling error. Recently, ultrasound elast...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016