The Laser Signature in Calibration of the Servomechanism

نویسندگان

  • Edward Plinski
  • Antoni Izworski
  • Jerzy Witkowski
چکیده

The laser signature, which can be observed as a result of the CO2 laser tuning, is used as a standard for calibration of the servomechanism. The servomechanism can be used for continuous investigations of the laser signatures of different laser media. Finally, some convenient signatures useful for a laser marker or single frequency laser operation can be find.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Design and Implementation of a Control System for a DC Servomechanism with an Internal Dither Created by a Limit Cycle

Purpose of this paper is designing of a positional angle control system for a DC servomechanism. The servomechanism system consists of a direct current (DC) motor, a motor driver, a measuring sensor, and a control board to adjust angular position. The motor in the servomechanism has a non-linear element called dead-zone. Presence of dead-zone causes the nonlinear behavior of system. Injecting a...

متن کامل

Design and Implementation of Discrete Time Observer Based Backstepping Controller for a 2DOF Servomechanism

The two degrees of freedom servomechanism has many applications, including in gimbaled seekers. These mechanisms require closed-loop control to perform properly. In this paper, an observer-based multi-input-multi-output hybrid controller is designed for a two-degree-of-freedom servomechanism. Since in the model presented in this paper, disturbances on the mechanism are considered, so an extende...

متن کامل

LabVIEW implementation of an enhanced nonlinear PID controller based on harmony search for one-stage servomechanism system

This paper presents a practical implementation for a new formula of nonlinear PID (NPID) control. The purpose of the controller is to accurately trace a preselected position reference of one stage servomechanism system. The possibility of developing a transfer function model for experimental setup is elusive because of the lack of system data. So, the identified model has been developed via gat...

متن کامل

A New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion

This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004