Reverse redistribution pattern in rest Tl-201 and stress Tc-99m SPECT in patients undergoing coronary interventions.

نویسندگان

  • Naoya Matsumoto
  • Shunichi Yoda
  • Ken Nagao
  • Atsushi Hirayama
چکیده

To cite: Matsumoto N, Yoda S, Nagao K, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014204325 DESCRIPTION A reverse redistribution pattern in rest thallium-201 (Tl)/stress technetium-99 m (Tc) tetrofosmin single photon emission CT (SPECT) is confusing. We present a myocardial perfusion SPECT in a 40-year-old patient undergoing coronary intervention in the left anterior descending coronary artery with an acute coronary syndrome. This pattern depicts a nearly normal perfusion in a resting Tl image and a perfusion defect in a stress Tc image, which indicates stress-induced ischaemia without significant coronary stenosis. This is frequently seen in patients who underwent an emergent reperfusion therapy. A nearly normal perfusion in a resting Tl image frequently changes into a perfusion defect mimicking a stress image in a 24 h delayed image (figure 1). This phenomenon can be explained by an excessive washout of Tl and Tc from the reperfused myocardium. Tl washout after reperfusion is well known as reverse redistribution. Washout of Tc agent is also reported in reperfused myocardium. In a rest Tl/stress Tc protocol, time course between the injection and imaging would be one of the reasons for reverse redistribution. A Tl/Tc protocol always requires rest-first imaging just after the Tl injection; this shorter time duration would not be enough for excessive washout. Therefore, a resting Tl image shows nearly normal perfusion. Conversely, post-stress images usually acquired 1 h after the injection for avoiding the emission of liver uptake. A 24 h delayed Tl image is enough to show reverse redistribution and it is an important procedure which can prevent misinterpretation after emergent percutaneous coronary interventions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Twenty-four-hour Tl-201 delayed scan underestimates myocardial viability in patients with acute myocardial infarction after percutaneous transluminal coronary angioplasty.

BACKGROUND Myocardial viability in area at risk of acute myocardial infarction (AMI) after reperfusion therapy may be underestimated by the 24-hour images due to reverse redistribution (r-RD). METHODS Subjects were 37 AMI patients in whom Tc-99m pyrophosphate (PYP)/Tl-201 dual-isotope SPECT was positive. The 24-hour delayed scan was performed with only a Tl window. One month later, follow up ...

متن کامل

Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging.

OBJECTIVES Our purpose was to describe a novel, rapid stress thallium-201 (Tl-201)/rest technetium-99m (Tc-99m) agent myocardial perfusion imaging (MPI) protocol (Tl/Tc) with a high-speed MPI scanner and to compare this protocol with a standard rest/stress Tc-99m agent protocol (Tc/Tc) with respect to image quality and radiation dosimetry. BACKGROUND Recent advances in gamma camera technology...

متن کامل

Quantitative rest technetium-99m tetrofosmin imaging in predicting functional recovery after revascularization: comparison with rest-redistribution thallium-201.

OBJECTIVES This study was undertaken to 1) compare the regional myocardial tracer distributions between rest technetium (Tc)-99m tetrofosmin and rest-redistribution thallium (Tl)-201 images in patients with coronary artery disease and left ventricular dysfunction; and 2) assess the comparative values of these agents for predicting functional recovery after revascularization. BACKGROUND Tc-99m...

متن کامل

Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease.

OBJECTIVES We compared dipyridamole technetium-99m (Tc-99m) tetrofosmin and thallium-201 (Tl-201) single-photon emission computed tomographic (SPECT) imaging with respect to the detection rate of perfusion abnormalities in 26 patients with angiographic coronary artery disease (CAD). BACKGROUND Experimental studies have shown that myocardial extraction of Tc-99m tetrofosmin is lower than that ...

متن کامل

Dose Nitroglycerine enhance detection of viable myocardium by Tl-201 SPECT? [Persian]

It is suggested that sublingual nitroglycerine can improve the ability of T1-201 for detection of viable myocardium. Methods and Results: In a randomized, double blind study, 50 patients who had fixed defects on stress-redistribution scan, were randomized into two groups. In group I, patients received 0.4-0.8 mg sublingual nitroglycerine, before T1-201 reinjection. In group II, reinjectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMJ case reports

دوره 2014  شماره 

صفحات  -

تاریخ انتشار 2014