Daily on-line set-up correction in 3D-conformal radiotherapy: is it feasible?
نویسندگان
چکیده
AIMS AND BACKGROUND The aim of this report was to investigate the feasibility in terms of treatment time prolongation of an on-line no-action level correction protocol, based on daily electronic portal image verification. METHODS AND STUDY DESIGN The occupation of a linear accelerator (LINAC) delivering 3-D conformal treatments was monitored for two weeks (from Monday to Friday, 10 working days). An electronic portal image device I-View (Elekta, UK) was used for setup verification. Single-exposure portal images were acquired daily using the initial 8 monitor units delivered for each treatment field. Translational deviations of isocenter position larger than 5 mm or 7 mm, for radical or palliative treatments, respectively, were immediately corrected. In order to estimate the extra workload involved with the on-line protocol, the time required for isocenter check and table correction was specifically monitored. RESULTS Forty-eight patients were treated. In all, 482 fractions had electronic portal images taken. Two hundred and forty-five setup corrections were made (50.8% of all fractions). The occupation of the LINAC lasted 106 h on the whole. Twelve h and 25 min (11.7% of LINAC occupation time) were spent for portal image verification and setup correction. On the average, 4.3 fractions per hour were carried out. CONCLUSIONS When used by trained therapists, ideally, portal imaging may be carried out before each fraction, requiring approximately 10% of LINAC occupation time.
منابع مشابه
Dosimetry evaluation of salivary glands in 3D conformal radiotherapy and intensity modulated radiotherapy in oral tongue cancer
Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer s...
متن کاملDosimetric Study of Tissue Heterogeneity Correction for Breast Conformal Radiotherapy
Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملThe comparison of dose distribution of different 3D conformal and conventional radiotherapy plans for gastric cancer
Aims: It was aimed to investigate postoperative conformal radiotherapy planning that provides the best target volume and the least dose for critical organs in cancers of stomach. Methods: This study was conducted on the CT simulation images of thirty patients diagnosed with gastric cancer. Target volumes and the organs at risk were contoured. AP-PA reciprocal parallel field conventional plan an...
متن کاملAssessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer
Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Tumori
دوره 98 4 شماره
صفحات -
تاریخ انتشار 2012