The Results of Internal Fixation of Proximal Humeral Osteoporotic Fractures with PHILOS Locking Plate.

نویسندگان

  • Ante Bandalović
  • Fabijan Cukelj
  • Josip Knežević
  • Marko Ostojić
  • Arsen Pavić
  • Zlatko Parać
  • Matko Rošin
چکیده

BACKGROUND In the last fifty years since plate and screw osteosynthesis has been implemented in fracture treatment, osteosporotic bone fractures were observed as a special problem. Due to special histologic, anatomic, physical and biomehanic properties of osteoporotic changed bone the laws of biomechanics suggest that stable osteosynthesis for osteoporotic bone is necessary to increase the contact surface of metallic implants and bone and the stability of the screw-plate-bone compound. There are numerous surgical techniques and methods for treatment of osteoporotic proximal humeral fractures. Every surgical procedure has to establish anatomical reduction and stable fixation that will enable early mobilisation. SUBJECTS AND METHODS The aim of this study was to present results of internal fixation of proximal humeral osteoporotic fractures with PHILOS locking plate. Between 2007 and 2012, a total of 67 patients older than 65 years with closed proximal humerus fractures underwent surgical treatment with PHILOS plate system (Synthes, Switzerland). 42 patients were operated with deltopectoral approach and 25 with deltoid split approach. After a mean follow up period of 14.68 (6-28) months functional and radiologic results were assessed. RESULTS We noted 9 postoperative complications related to surgical technique (1 intraarticular screw placement, 1 displacement in major tuberculum fragment, 1 displacement in major tuberculum fragment along with oblique placement of the plate, 2 cases of inadequate reduction, 1 case of humeral head avascular necrosis, varus humeral head fixation in 3 cases). None of the patients developed superficial or deep surgical infection. There was no nonunions. In the final evaluation, the Constant shoulder score was 91.75 (72-100). CONCLUSIONS In this study PHILOS locking plate showed good applicability, respecting bone biologic properties because of negligible interference with blood supply of the humeral head. There was no requirement to shape the plate enabling stabilization at constant angles as clear benefit of this plate. All that enables early mobilisation, and no implant insufficiency resulting in satisfactory treatment results and high Constant shoulder scores.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer representation of osteosynthesis stability in locking plates used for the treatment of osteoporotic proximal humerus fractures.

BACKGROUND Proximal humerus fractures are represented as 4-5% of all fractures, with incidence notably growing with age. Since surgical internal fixation in treatment of proximal humeral fractures is used, fractures of osteoporotic bone and choice of plate for their osteosynthesis represent particular problem. The aim of the study was to test two locking plates: Philos plate with locking screws...

متن کامل

Outcome of proximal humerus fractures treated by PHILOS plate internal fixation. Experience of a district general hospital.

Proximal humerus fractures have been a challenge to achieve stable fixation. PHILOS (Proximal Humerus internal locking system) is part of the latest generation of locking compression plates for proximal humeral fracture fixation. We aim to assess the clinical and functional outcome of proximal humeral fractures (2-part, 3-part and 4-part) treated with the PHILOS plate. We prospectively reviewed...

متن کامل

PHILOS Plate: Is it the Panacea for all Proximal Humerus Fractures?

Proximal humerus fractures are common and have a bimodal age distribution. Fracture-dislocations in younger patients result from highenergy trauma and most surgeons attempt open reduction and internal fixation, if at all possible. Osteoporotic fractures in elderly patients are commonly associated with low-energy trauma such as groundlevel falls and most are minimally displaced, impacted fractur...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Osteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results

UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Psychiatria Danubina

دوره 26 Suppl 2  شماره 

صفحات  -

تاریخ انتشار 2014