A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results.

نویسندگان

  • S J Doran
  • K K Koerkamp
  • M A Bero
  • P Jenneson
  • E J Morton
  • W B Gilboy
چکیده

Methods based on magnetic resonance imaging for the measurement of three-dimensional distributions of radiation dose are highly developed. However, relatively little work has been done on optical computed tomography (OCT). This paper describes a new OCT scanner based on a broad beam light source and a two-dimensional charge-coupled device (CCD) detector. A number of key design features are discussed including the light source; the scanning tank, turntable and stepper motor control; the diffuser screen onto which images are projected and the detector. It is shown that the non-uniform pixel sensitivity of the low-cost CCD detector used and the granularity of the diffuser screen lead to a serious ring artefact in the reconstructed images. Methods are described for eliminating this. The problems arising from reflection and refraction at the walls of the gel container are explained. Optical ray-tracing simulations are presented for cylindrical containers with a variety of radii and verified experimentally. Small changes in the model parameters lead to large variations in the signal intensity observed in the projection data. The effect of imperfect containers on data quality is discussed and a method based on a 'correction scan' is shown to be successful in correcting many of the related image artefacts. The results of two tomography experiments are presented. In the first experiment, a radiochromic Fricke gel sample was exposed four times in different positions to a 100 kVp x-ray beam perpendicular to the plane of imaging. Images of absorbed dose with slice thickness of 140 microm were acquired. with 'true' in-plane resolution of 560 x 560 microm2 at the edge of the 72 mm field of view and correspondingly higher resolution at the centre. The nominal doses measured correlated well with the known exposure times. The second experiment demonstrated the well known phenomenon of diffusion in the dosemeter gels and yielded a value of (0.12 +/- 0.02) mm2 s(-1) for the diffusion coefficient of the xylenol orange/iron complex. Finally, the overall implications of the above findings for dosimetry using OCT are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and developing an in-house CCD based optical CT scanner for gel dosimetry

Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

A practical three-dimensional dosimetry system for radiation therapy.

There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. Here we introduce a dosimetry system that can achieve this challenge, consisting of a radiochromic dosimeter (PRESAGE) and a commercial optic...

متن کامل

Preliminary commissioning investigations with the DMOS-RPC optical-CT Scanner.

A midsized broad beam Optical-CT scanner is being developed for collaborative research between Duke and the Radiological Physics Center (RPC). The Duke Midsized Optical-CT Scanner (DMOS-RPC) is designed to be compatible with several of the RPC phantoms, including the head and neck, stereotactic SRS, and lung phantoms. Preliminary data investigating the basic performance of the scanner is descri...

متن کامل

Development of a new laser-line and CCD based optical-CT scanner for the readout of 3D radiation dosimeters

We present initial results on the comparison of the dose readout from a three dimensional polymer gel dosimeter using two different optical-CT systems; i) a common wide field and a wide area detector optical-CT system and ii) a new ‘laser-line’ and wide area detector based optical-CT system. The findings presented herein highlight the advantage of the laser based over the wide field optical-CT ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 46 12  شماره 

صفحات  -

تاریخ انتشار 2001