Correlation of bioluminescent assay of gentamicin in serum with agar diffusion assay, latex agglutination inhibition card test, enzyme immunoassay, and fluorescence immunoassay.
نویسنده
چکیده
An improved bioluminescent assay of gentamicin in serum, based on the dose-dependent effect of the agent on the accumulation of extracellular ATP in Escherichia coli LU 14 cultures, is presented. The accuracy of the bioluminescent assay of gentamicin, expressed as the mean coefficient of variation over the therapeutic range, was 2.8%. Corresponding figures for an agar diffusion assay, a latex agglutination inhibition card test, an enzyme immunoassay, and a fluorescence immunoassay were 6.4, 17.5, 4.2, and 9.4%, respectively. All of the methods correlated well (r = 0.926 to 0.976), with the possible exception of the card test (r = 0.777 to 0.841). The bioluminescent assay requires only 1 microliter of serum, which allows for capillary sampling, and results are available within 75 min.
منابع مشابه
Evaluation of five gentamicin assay procedures for clinical microbiology laboratories.
Five gentamicin assay procedures (a bioassay, an enzyme immunoassay, a latex agglutination inhibition test, a fluorescence immunoassay, and a radioimmunoassay) were evaluated to determine which was optimal for our laboratory. The evaluation was based on recovery and precision studies and results of analyses of patient samples, as well as technical assay performance factors. The latex agglutinat...
متن کاملDevelopment of a Latex Agglutination Method for Diagnosis of Rotavirus Infections
Background: Rotavirus is a major cause of morbidity and mortality among children with gastroenteritis. Since the discovery of rotaviruses, several techniques have been used for their laboratory diagnosis; those included Electron Microscopy (EM) and enzyme immunoassay. These methods, however, are expensive and not readily available everywhere. We have developed a technique which can be used for ...
متن کاملLatex agglutination inhibition card test for gentamicin assay: clinical evaluation and comparison with radioimmunoassay and bioassay.
Gentamicin levels were determined in 100 serum specimens by a new latex agglutination inhibition card test, a radioimmunoassay (RIA), and a bioassay. Correlation coefficients determined by linear regression analysis demonstrated that the levels obtained by the latex agglutination inhibition card test had a high degree of correlation with the RIA and could be performed much faster and more econo...
متن کاملEvaluation of a new latex test and a new enzyme immunoassay for determination of rubella immunity.
A new enzyme immunoassay (Rubenostika; Organon Teknika, Turnhout, Belgium), a new latex agglutination test (Rubalex; Orion Diagnostica, Espoo, Finland), and three other accepted methods for the determination of rubella immunity were compared with a standard hemagglutination inhibition assay. Of 224 serum samples tested, 54 (24%) were nonreactive and 24 (11%) were low titered. All procedures wer...
متن کاملEvaluation of an automated fluorescence polarization immunoassay for vancomycin.
An automated fluorescence polarization immunoassay for the determination of vancomycin levels in serum was evaluated. The vancomycin assay is a homogeneous competitive inhibition immunoassay based on changes in fluorescence polarization that occur with antibody binding. This assay was compared with a liquid chromatographic assay and an agar well diffusion bioassay method by using clinical serum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 20 3 شماره
صفحات -
تاریخ انتشار 1984