A compact design for beam transport

نویسندگان

  • Gerard J. Ernst
  • Jan I.M. Botman
چکیده

A double-achromatic, double-focusing magnet system of very small size is described which will be used in the injection line for an undulator in a FEL experiment . Because of the double focusing no quadrupoles are needed between the dipole, which couples the electrons in the FEL cavity, and the undulator. An example will be worked out for an electron bunch of 25 MeV, 100 Awhich is focused on a spot of 1 mm diameter .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Simulation of Photoneutron Source by MCNPX Monte Carlo Code for Boron Neutron Capture Therapy

Introduction Electron linear accelerator (LINAC) can be used for neutron production in Boron Neutron Capture Therapy (BNCT). BNCT is an external radiotherapeutic method for the treatment of some cancers. In this study, Varian 2300 C/D LINAC was simulated as an electron accelerator-based photoneutron source to provide a suitable neutron flux for BNCT. Materials and Methods Photoneutron sources w...

متن کامل

Optimised BNCT facility based on a compact D-D neutron generator

Background: Boron Neutron Capture Therapy (BNCT) is a very promising treatment for patients suffering gliobastoma multiforme, an aggressive type of brain cancer, where conventional radiation therapies fail. Thermal neutrons are suitable for the direct treatment of cancers which are located at near-tissue-surface deep-seated tumors need harder, epithermal neutron energy spectra. Materials and Me...

متن کامل

Compact Medical Cyclotrons and their use for Radioisotope Production and Multi-disciplinary Research

Compact medical cyclotrons are conceived for radioisotope production in a hospital-based environment. Their design in terms of field shape, stability and radio-frequency (RF) is aimed at obtaining high intensity (>150 μA) beams at kinetic energies of the order of 20 MeV. To guarantee high performances, an optimization procedure during the commissioning phase is crucial as well as a regular prev...

متن کامل

Development of a compact superconducting rotating-gantry for heavy-ion therapy

An isocentric superconducting rotating-gantry for heavy-ion therapy is being developed [1]. This rotating gantry can transport heavy ions having 430 MeV/u to an isocenter with irradiation angles of over ±180°, and is further capable of performing fast raster-scanning irradiation [2]. A layout of the beam-transport line for the compact rotating-gantry is presented in Fig. 1. The rotating gantry ...

متن کامل

Design of a Compact All-permanent Magnet Ecr Ion Source Injector for Rea at the Msu Nscl

The design of a compact all-permanent magnet electron cyclotron resonance (ECR) ion source injector for the ReAccelerator Facility (ReA) at the Michigan State University (MSU) National Superconducting Cyclotron Laboratory (NSCL) is currently being carried out. The ECR ion source injector will augment the electron beam ion trap (EBIT) charge breeder as an off-line stable ion beam injector for th...

متن کامل

A COMPACT 2.45 GHz MICROWAVE ION SOURCE BASED HIGH FLUENCE IRRADIATION FACILITY AT IUAC, DELHI

A compact 2.45 GHz microwave ion source based low energy ion been facility has been developed for performing various experiments in material science and for studies related to plasma physics. The design of the compact microwave source is based on a tunable permanent magnet configuration and is powered by a 2 kW magnetron [1,2]. The double walled, water cooled stainless steel plasma chamber and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002