Dynamic Geometrical Calibration for 3-D Cerebral Angiography
نویسندگان
چکیده
Recently there has been increasing interest in obtaining three-dimensional reconstructions of arterial vessels from multiple planar radiographs (obtained at angles around the object). Interventional angiography is the motivating application behind this research. Different methods have been proposed to acquire the planar data such as a gantry mounted x-ray image intensifier (XRII) or a C-arm mounted XRII. In order to obtain a threedimensional reconstruction from a C-arm mounted XRII the trajectory of the source and detector system must be characterized. We have designed a calibration system that provides the necessary trajectory information using uniquely identifiable markers positioned on a cylinder. This calibration ring is to be placed around the patient's head, and consists of steel balls positioned in a predefined arrangement on a cylindrical acrylic support. The balls are arranged such that calibration can be done from almost any partial view, allowing reconstruction of a region of interest (ROl). Steel balls are placed around an acrylic cylinder, restricted to a band approximately 8.5 mm wide, thereby obscuring only a small fraction of the image. In this case the radiograph includes the region of interest (ROT) as well as a partial view of the calibration ring. This enables us to recover the geometry of X-ray imaging system from each individual frame. We call this process "dynamic calibration" as opposed to "off-line" calibration procedures which try to characterize the motion of C-arm before introducing the patient.
منابع مشابه
Cerebral aneurysms: detection and delineation using 3-D-CT angiography.
PURPOSE We compared three-dimensional image (3-D-CT) angiography with conventional angiography to determine the clinical usefulness of this technique. MATERIALS AND METHODS We studied 15 patients with cerebral aneurysms using dynamic CT with intravenous injection of contrast material and reconstructed 3-D-CT angiography. RESULTS 3-D-CT angiography could be performed in conjunction with stan...
متن کاملCerebral aneurysms: evaluation with three-dimensional CT angiography.
PURPOSE To evaluate the usefulness of three-dimensional CT angiography (CTA), in which contrast material is used to create reformations of dynamic scans, in the diagnosis and the preoperative evaluation of cerebral aneurysms. METHODS We used 3-D CTA to examine 65 patients with suspected or angiographically verified cerebral aneurysms. A blind study was performed to evaluate the diagnostic acc...
متن کاملBrain death: use of dynamic CT and intravenous digital subtraction angiography.
Brain death results when irreversible intracranial circulatory arrest, involving both the internal carotid and intracranial vertebral basilar systems, occurs despite preservation of extracranial circulation . To document the absence of intracranial blood flow and establish the irreversibility of the condition, intraarterial cerebral angiography and radionuclide cerebral angiography have become ...
متن کاملTransradial Neurointerventional Approach to Basilar Tip Aneurysm: Case Report and Technical Note
Cerebral angiography through transfemoral approach is preferred in most of the situation though in cardiovascular surgery transradial angiography is accounted as the superior standard. The present study aimed at presenting our early experience of transradial approach to cerebral angiography and intervention of a patient with basilar tip aneurysm that had inappropriate vasculature to perform rou...
متن کاملNovel dynamic four-dimensional CT angiography revealing 2-type motions of cerebral arteries.
BACKGROUND AND PURPOSE We developed a novel dynamic 4-dimensional CT angiography to accurately evaluate dynamics in cerebral aneurysm. METHODS Dynamic 4-dimensional CT angiography achieved high-resolution 3-dimensional imaging with temporal resolution in a beating heart using dynamic scanning data sets reconstructed with a retrospective simulated R-R interval reconstruction algorithm. RESUL...
متن کامل