CFD Simulation and Optimisation of a Low Energy Ventilation and Cooling System

نویسندگان

  • John Kaiser Calautit
  • Dominic O'Connor
  • Polytimi Sofotasiou
  • Ben Richard Hughes
چکیده

Mechanical Heating Ventilation and Air-Conditioning (HVAC) systems account for 60% of the total energy consumption of buildings. As a sector, buildings contributes about 40% of the total global energy demand. By using passive technology coupled with natural ventilation from wind towers, significant amounts of energy can be saved, reducing the emissions of greenhouse gases. In this study, the development of Computational Fluid Dynamics (CFD) analysis in aiding the development of wind towers was explored. Initial concepts of simple wind tower mechanics to detailed design of wind towers which integrate modifications specifically to improve the efficiency of wind towers were detailed. From this, using CFD analysis, heat transfer devices were integrated into a wind tower to provide cooling for incoming air, thus negating the reliance on mechanical HVAC systems. A commercial CFD code Fluent was used in this study to simulate the airflow inside the wind tower model with the heat transfer devices. Scaled wind tunnel testing was used to validate the computational model. The airflow supply velocity was measured and compared with the numerical results and good correlation was observed. Additionally, the spacing between the heat transfer devices was varied to optimise the performance. The technology presented here is subject to a patent application (PCT/GB2014/052263).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

Improvement of thermal performance of a solar chimney based on a passive solar heating system with phase-change materials

Passive solar systems such as solar chimneys need solar radiation in order to work. Therefore, they cannot present stable natural ventilation when solar energy vanishes: to have a more robust and stable condition, solar energy should be stored during the day and released back during the night. Phase change materials can save additional thermal energy during the day and release it during the...

متن کامل

Improvement of thermal performance of a solar chimney based on a passive solar heating system with phase-change materials

Passive solar systems such as solar chimneys need solar radiation in order to work. Therefore, they cannot present stable natural ventilation when solar energy vanishes: to have a more robust and stable condition, solar energy should be stored during the day and released back during the night. Phase change materials can save additional thermal energy during the day and release it during the nig...

متن کامل

Experimental and Numerical Investigations on Al2O3–Tricosane Based Heat Pipe Thermal Energy Storage

The enhancement of operating life cycle of electronic devices necessitates the development of efficient cooling techniques. Therefore, in the present work the effects of employment of Phase Change Material, in the adiabatic section of heat pipe for electronic cooling applications were experimentally and numerically investigated. Tricosane (100 ml) is chosen as PCM in this study, where Al2O3 nan...

متن کامل

Effect of Velocity and Direction of Airflow on Thermal Comfort and Energy Consumption: Case of New Exclusive Cooling Systems

The application of personalized ventilation systems, particularly in the buildings, is one of the new topics that today presented to it, because of their proper performance in reducing energy consumption and creating better thermal comfort conditions. In the current study, the energy consumption of a personalized cooling system installed in a room, considering the constraint of thermal comfort,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computation

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015