Six-Fold Acceleration of High-Spatial Resolution 3D SPACE MRI of the Knee Through Incoherent k-Space Undersampling and Iterative Reconstruction-First Experience.
نویسندگان
چکیده
PURPOSE The aim of this study was to prospectively test the hypothesis that 6-fold acceleration of a 3-dimensional (3D) turbo spin echo (TSE) magnetic resonance imaging (MRI) pulse sequence with k-space undersampling and iterative reconstruction is feasible for fast high spatial resolution MRI of the knee, while yielding similar image quality and diagnostic performance when compared with a conventional 2-dimensional (2D) TSE MRI standard. MATERIALS AND METHODS The study was approved by the institutional review board. A 10-minute isotropic 3D TSE knee protocol consisting of accelerated intermediate-weighted (repetition time, 900 milliseconds; echo time, 29 milliseconds; voxel size, 0.5 × 0.5 × 0.5 mm; acquisition time, 4:45 minutes) and fat-saturated T2-weighted (repetition time, 900 milliseconds; echo time, 92 milliseconds; voxel size, 0.5 × 0.5 × 0.5 mm; acquisition time, 5:10 minutes) SPACE (sampling perfection with application optimized contrast using different flip angle evolutions) sequence prototypes was compared against a 20-minute 2D TSE standard protocol. The accelerated SPACE sequences were equipped with an optional variable-density poisson-disc pattern as an undersampling mask. An undersampling factor of 0.17 was chosen (6-fold acceleration compared with an acquisition with full sampling). An iterative, sensitivity encoding-type reconstruction with L1 norm-based regularization term was used. The study was performed on a 3 T MRI system using a 15-channel transmit/receive knee coil. The study groups included 15 asymptomatic volunteers and 15 patient volunteers. Quantitative and qualitative assessments were performed by 2 observers. Outcome variables included signal and contrast-to-noise ratio, image quality, and diagnostic accuracy. Qualitative and quantitative measurements were statistically analyzed using nonparametric tests. P values of less than 0.01 were considered significant. RESULTS The signal-to-noise ratios of 2D and 3D MRI were similar with the exception of fluid, which was brighter on 2D MRI. Relevant contrast-to-noise ratios of 2D MRI were higher than 3D MRI; however, observer ratings for satisfaction, image quality, and visibility of anatomic structures were similar for 2D and 3D MRI. There was moderate to excellent interobserver (κ = 0.54-1.00) and intermethod (κ = 0.54-1.00) agreement for assessing menisci, cartilage, ligaments, cartilage, and bone. Two-dimensional and 3D MRI had similar sensitivity (100%/100%, respectively) and specificity (87%/75%, respectively) for detecting 9 meniscal tears (P = 1.00). CONCLUSIONS We demonstrate the successful clinical implementation of 3D TSE MRI with incoherent k-space undersampling and iterative reconstruction for 6-fold accelerated high spatial resolution isotropic 3D MRI data acquisition. Our preliminary assessments suggest similar image quality and diagnostic performance of a comprehensive 10-minute 3D TSE MRI prototype protocol and 20-minute TSE MRI standard protocol.
منابع مشابه
Combination of Compressed Sensing, Parallel Imaging and Partial Fourier for Highly-Accelerated 3D First-Pass Cardiac Perfusion MRI
Introduction: First-pass myocardial perfusion MRI is a promising and noninvasive technique for evaluation of ischemic heart disease. 3D whole-heart coverage per heartbeat is desirable for clinical perfusion studies to overcome the contrast-to-noise ratio (CNR) and volumetric coverage limitations associated with multi-slice 2D perfusion MRI studies [1-2]. Highly accelerated imaging is a necessar...
متن کاملAccelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k
Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...
متن کاملCompressed sensing reconstruction for whole-heart imaging with 3D radial trajectories: a graphics processing unit implementation.
A disadvantage of three-dimensional (3D) isotropic acquisition in whole-heart coronary MRI is the prolonged data acquisition time. Isotropic 3D radial trajectories allow undersampling of k-space data in all three spatial dimensions, enabling accelerated acquisition of the volumetric data. Compressed sensing (CS) reconstruction can provide further acceleration in the acquisition by removing the ...
متن کاملAccelerated MRI thermometry by direct estimation of temperature from undersampled k-space data.
PURPOSE Acceleration of magnetic resonance (MR) thermometry is desirable for several applications of MR-guided focused ultrasound, such as those requiring greater volume coverage, higher spatial resolution, or higher frame rates. METHODS We propose and validate a constrained reconstruction method that estimates focal temperature changes directly from k-space without spatial or temporal regula...
متن کاملHighly Undersampled 3D Golden Ratio Radial Imaging with Iterative Reconstruction
Introduction Compressed Sensing (CS) [1,2] suggests that using nonlinear reconstruction algorithms based on convex optimization an accurate signal reconstruction can be obtained from a number of samples much lower than required by the Nyquist limit. Recently, CS was demonstrated for MR imaging from undersampled data [3, 4]. Prerequisites for a good image reconstruction are the image compressibi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative radiology
دوره 51 6 شماره
صفحات -
تاریخ انتشار 2016