Automated quantification of thyrotropin by radial partition immunoassay.

نویسندگان

  • J A Rugg
  • C W Flaa
  • S R Dawson
  • C T Rigl
  • K S Leung
  • S A Evans
چکیده

We describe a radial partition enzyme immunoassay in which fully automated quantification of human thyrotropin (hTSH) takes less than 11 min. This "sandwich"-type assay involves two monoclonal antibodies, both specific for the intact hTSH molecule. The solid phase consists of tabs of glass-fiber filter paper containing a pre-immobilized monoclonal anti-hTSH antibody complexed with a goat antibody specific for the Fc region of mouse IgG. The patient's sample is first applied to the central "reaction zone" of the tab, wherein hTSH binds to the immobilized antibody. Application of a buffered solution containing enzyme-labeled Fab' fragments of the second monoclonal anti-hTSH antibody initiates "sandwich" formation. A wash buffer containing a fluorogenic substrate elutes unbound conjugate to the tab periphery. The bound enzyme conjugate is quantified by measuring the rate of increase in fluorescence in the reaction zone of the tab, then converting the rate to clinical units by comparison with a stored calibration curve. The clinical utility and performance of the present assay compare favorably with those of other sensitive assays for hTSH.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interference in an automated radial partition fluorescent immunoassay of thyrotropin associated with liver-function abnormalities.

In a previous evaluation of a "sensitive" radial partition fluorescent immunoassay on the Stratus system, thyrotropin (TSH) values exhibited a positive bias in icteric samples when compared with results of a nonsensitive radioimmunoassay. In the present study, we evaluated 366 patients samples to assess whether any biochemical markers of liver function could identify samples for which TSH value...

متن کامل

Radial partition immunoassay applied to automated quantification of human choriogonadotropin with use of two monoclonal antibodies.

We describe a novel application of radial partition immunoassay to quantification of human choriogonadotropin (hCG). In this "sandwich"-type assay, two monoclonal antibodies, specific for different sites on the intact molecule are used. The solid phase consists of tabs of glass-fiber filter paper containing a pre-immobilized antibody specific for the alpha subunit of hCG. The patient's sample i...

متن کامل

Automated quantification of creatine kinase MB isoenzyme in serum by radial partition immunoassay, with use of the Stratus analyzer.

We evaluated the analytical and clinical performances of a new radial partition immunoassay for measuring the mass concentration of creatine kinase (CK)-MB in serum. All pipetting, washes, incubations and data reduction were performed in 8 min by the Stratus (Dade) fluorometric analyzer. Within-assay and between-assay CVs were respectively 5.5% and 8.4% at 21 micrograms/L, and 4.2% and 3.4% at ...

متن کامل

Quantification of Human Chorionic Gonadotropin by Bovine Serum Albumin Nanoparticles

Background and Aims: Some nanoparticles can be used in immunoassays to increase sensitivity. This study aimed to evaluate a novel nano-immunoassay based on bovine serum albumin nanoparticles (BSA NPs). Materials and methods: At first, the nanostructure was synthesized, and then applied as a tag in the nano-immunoassay. Then the concentration of β-subunit of human chorionic gonadotropin ...

متن کامل

Quantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods

Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 1988