High-accuracy ultrasound target localization for hand-eye calibration between optical tracking systems and three-dimensional ultrasound

نویسندگان

  • Ralf Bruder
  • Florian Griese
  • Floris Ernst
  • Achim Schweikard
چکیده

Real-time target localization in ultrasound is useful in many clinical and scientific areas. For example in radiation therapy tumors can be localized in real-time and irradiated with a high accuracy. To measure the position of an ultrasound target in a global coordinate system or to extend the tracking volume by moving the ultrasound transducer an optical marker is attached to it and observed by an optical tracking system. The necessary calibration matrices from marker to ultrasound volume are obtained using hand-eye calibration algorithms which take sets of corresponding observations of the optical marker and an ultrasound target as input. The quality of these calibration matrices is highly dependent on the measured observations. While the accuracy of optical tracking systems is very high, accurate tracking in ultrasound is difficult because of the low resolution of the ultrasound volume, artifacts and noise. Therefore accurate hand-eye calibration is difficult between ultrasound and optical tracking systems. We have tested different phantoms, matchingand sub-pixel strategies to provide highly accurate tracking results in 3D ultrasound volumes as basis for hand-eye calibration. Tests have shown that – using the described methods calibration results with RMS errors of less than 1mm between observed and calibrated targets can be reached.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Efficient Platform for Freehand US Calibration

Freehand three-dimensional ultrasound system allows intra-operative imaging of pathologic tissue for image-guided injection. Accurate registration of ultrasound image for injection navigation requires calibration that is timeconsuming and tedious. We present an efficient calibration system based on a clinical injector. The injector equipped with an optical tracking sensor is moved in the vicini...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

Calibration of Swept-Volume 3D Ultrasound

We present two different methods for calibrating 3D swept-volume ultrasound as a prerequisite for an ultrasound based intraoperative navigation system. Different solutions of the calibration problem for 2D ultrasound exist, but no approach has been published so far that takes advantage of 3D swept-volume ultrasound. In contrast to 3D freehand ultrasound no compounding has to be performed. Inste...

متن کامل

Active Echo: A New Paradigm for Ultrasound Calibration

In ultrasound-guided medical procedures, accurate tracking of interventional tools with respect to the US probe is crucial to patient safety and clinical outcome. US probe tracking requires an unavoidable calibration procedure to recover the rigid body transformation between the US image and the tracking coordinate system. In literature, almost all calibration methods have been performed on pas...

متن کامل

Cardiac Motion Analysis Based on Optical Flow on Real-Time Three- Dimensional Ultrasound Data

With relatively high frame rates and the ability to acquire volume data sets with a stationary transducer, 3D ultrasound systems, based on matrix phased array transducers, provide valuable three-dimensional information, from which quantitative measures of cardiac function can be extracted. Such analyses require segmentation and visual tracking of the left ventricular endocardial border. Due to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011