Dependence of Radar Emission Spectra on Measurement Bandwidth and Implications for Compliance with Emission Mask Criteria
نویسنده
چکیده
Radar transmitter emission criteria normally include the specification of frequency-dependent emission masks. These masks specify the amount by which unwanted radar emissions (both out-of-band and spurious) must be suppressed relative to the power levels emitted at the radars fundamental frequencies. Compliance with emission masks is determined through measurements of emission spectra. The measured levels of radar unwanted emissions and fundamental-frequency emissions both vary as a function of measurement system bandwidth, Bm. But the variation with Bm differs between the unwanted emissions and the fundamental-frequency emissions. Moreover, the variation of unwanted emission levels varies as a function of frequency as well as Bm. This creates a problem for radar emission mask-compliance measurements. The National Telecommunications and Information Administration (NTIA) Institute for Telecommunication Sciences (ITS) has explored this problem by performing emission spectrum measurements on a maritime surface search (navigation) radar. In the spectrum data that are presented, the radar unwanted emission levels are found to vary between 12 log(Bm) and 20 log(Bm), depending upon frequency. But the measured power of the radar fundamental frequency is found to vary as 20 log(Bm) for all bandwidths that are less than or equal to 1/(radar pulse width). The result is that the level offset between the unwanted emissions and the fundamental-frequency emission level depends upon the measurement bandwidth and the frequency of the unwanted emissions. This result implies, at a minimum, that measurement personnel must take the effect of Bm into account when performing radar emission spectrum measurements for the purpose of determining emission mask compliance. Based upon the results of these maritime radar spectrum data, some technical strategies for measuring radar emission spectra for emission mask compliance are proposed. Possible technical implications for future development of radar emission masks are also discussed.
منابع مشابه
Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data
Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...
متن کاملA new method for Eosin preparation and examination of its absorption and emission spectra
Eosin is one of the original dyes of xanthenes derivatives. It is also one of the main derivatives of fluorescein and has brilliant fluorescence. Eosin disodium salt called "Eosin Y" is the most useful form of this compound. In common procedures, eosin is usually obtained by the action of bromine on fluorescein, which has not good yield and purity degree. In this research, it is prepared by the...
متن کاملModulation Response and Relative Intensity Noise Spectra in Quantum Cascade Lasers
Static properties, relatively intensity noise and intensity modulation response in quantum cascade lasers (QCLs) studied theoretically in this paper. The present rate equations model consists of three equations for the electrons density in the conduction band and one equation for photons density in cavity length. Two equations were derived to calculate the noise and modulation response. Calcula...
متن کاملOn the Dependence of Soot Formation and Combustion on Swirling Combustion Furnaces: Measurement and Simulation
Soot concentration distribution is investigated both numerically and experimentally in methane-air diffusion flame. The experimental work is conducted with a cylindrical swirl stabilized combustor. Filter paper technique is used to measure soot volume fraction inside the combustor. The numerical simulation is based on the solution of the fully-coupled conservation equations for swirling turbule...
متن کاملThe effect of doping Graphene Quantum Dots with K, B, N, and Cl on its emitted spectrum
In this work, the effect of doping Graphene Quantum Dots (GQDs) on their emission spectra has been studied. First, graphene has been deposited on SiC substrate by using sublimation method. Second, doped-GQDs have been distributed on the surface of graphene via drop casting. The structure of the samples have been studied and characterized by X-ray diffraction (XRD), Scanning Electron Microscopy ...
متن کامل