Volar plate fixation for the treatment of distal radius fractures: analysis of adverse events.

نویسندگان

  • Luigi Tarallo
  • Raffaele Mugnai
  • Francesco Zambianchi
  • Roberto Adani
  • Fabio Catani
چکیده

OBJECTIVES Determining the rate of specific adverse events after volar plating performed for distal radius fractures. DESIGN Retrospective. SETTING University level I trauma center. PATIENTS We searched the electronic database of all surgical procedures performed in our department using the following keywords: distal radius fracture, wrist fracture, and plate fixation. We identified 315 patients, 12 of whom were lost at follow-up. INTERVENTION Volar plate fixation for the treatment of distal radius fractures. MAIN OUTCOME MEASUREMENTS At an average follow-up of 5 years, 303 patients were evaluated through medical records and clinical and radiographic assessment for specific adverse events after volar plate fixation. RESULTS Adverse events were observed in 18 patients (5.9%). Implant-related adverse events, including tendon impairments, intra-articular screws, and screw loosening, were observed in 15 patients (5.0%). Extensor tendon impairments were represented by 5 cases of extensor tenosynovitis and 3 cases of rupture of the extensor pollicis longus due to screws protruding dorsally. Flexor impairments were represented by 2 cases of tenosynovitis and 2 cases of flexor pollicis longus rupture. Screw penetration into the radioulnar joint was observed in 1 case. Loss of reduction was identified in 3 cases. One patient had a deep postoperative infection treated with operative debridement. One patient experienced injury to the median nerve during routine implant removal unrelated to tendon issues. CONCLUSIONS The majority of adverse events after volar plate fixation were due to technical errors in implant placement. In our cohort, tendon impairments were the most frequently observed; among these, extensor tendon impairments were the most represented (50% of all adverse events). All 12 tendon-related adverse events were due to technical shortcomings with implant placement. LEVEL OF EVIDENCE Therapeutic level IV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volar locking plate fixation versus Kirschner wire fixation in distal radius fractures: a meta-analysis

Objective: The superiority of volar locking plate fixation and K-wire fixation on treatment of distal radius fractures was controversial. Thus, we performed a meta-analysis to compare the efficacy of volar locking plate and K-wires for distal radius fracture. Methods: We searched Embase, Medline and PubMed for randomized controlled trials which compare the effects of volar locking plate and K-w...

متن کامل

Stainless steel versus titanium volar multi-axial locking plates for fixation of distal radius fractures: a randomised clinical trial

BACKGROUND Distal radius fractures are among the most common fractures seen in the hospital emergency department. Of these, over 40% are considered unstable and require some form of fixation. In recent years with the advent of low profile plating, open reduction and internal fixation (ORIF) using volar plates has become the surgical treatment of choice in many hospitals. However, it is currentl...

متن کامل

Distal Radius Fractures: What Cannot Be Fixed With a Volar Plate?—The Role of Fragment-Specific Fixation in Modern Fracture Treatment

The advent of volar fixed-angle plate osteosynthesis has greatly improved the technical ability of the surgeon to treat distal radius fractures and expanded the indications for operative treatment. Nevertheless, the volar plate is not a panacea for all distal radius fractures. Increasingly, it has been recognized that the loss of fixation, secondary displacement, and lack of stability can occur...

متن کامل

Comparison of close reduction and percutaneous pin fixation as treatments for distal metaphyseal radius fractures

Background: Distal radius fractures are one of the most common fractures of skeletal system and because of the aging of population, its incidence is rising. The aim of the present research was to evaluate the close reduction and percutaneous pin fixation as a treatment option. Material and methods: 44 patients who were type 2 according to universal classification or type 2 or 3 according to Ol...

متن کامل

Volar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.

Volar locking plate (VLP) fixation has become the standard surgical treatment for distal radius fractures. However, flexor tendon rupture is one of the major complications following volar plating. This detailed review on the anatomy and morphology of the volar distal radius might facilitate appropriate placement of the volar plate and thereby avoid flexor tendon rupture. We introduce safe and s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 2013