AB11. New technology of 3D imaging/reconstruction for robotic renal surgery
نویسنده
چکیده
In recent year s , l aparoscop ic rad ica l prostatectomy (LRP) has been established as a safe and effective treatment for localized prostate cancer. With better visualization of the anatomy, LRP has the potential to provide a gold standardization for prostate cancer. However, outcomes include urinary incontinence, bleeding and sexual dysfunction, which can have significant adverse effects on quality of life, remains a huge challenge. Here, we have performed laparoscopic radical anatomy of prostatectomy for localized prostate cancer, and obtained satisfactory effects. Experience including: We are familiar with the local anatomy of prostate in preoperative, and carefully identify important anatomic symbols, such as bilateral fascia reflexed, the junction of bladder and prostate in intraoperative; We identify correct anatomy of prostate to avoid blind clamp, burning, and properly handle the fascia reflexed, penile deep dorsal neurovascular complex and prostate lateral ligament to avoid blood loss; We are carefully isolate the junction of bladder neck and prostate, which is an important part of controlling urination; Fully open Dirichlet fascia when we isolate the dorsal prostate, and along the anterior rectum gap close to the prostate to separate the apex of prostate; It is as much as possible to retain the urethral length when the separation of the apex of the prostate, and cut off urethra close to the apex of the prostate with scissors; Then a careful dissection of the prostate laterally from its periprostatic fascia was performed with preservation of the nerves and vessels contained in the fascias, we open Dirichlet fascia along the seminal vesicle basal, close to the prostatic fascia isolate prostate dorsal until the apex of the prostate called as interfascial technique, and cut off the endopelvic fascia only ventrally and medially to the puboprostatic ligaments were spared called as intrafascial technique; Single needle suture plus V-Loc one-way barbs suture in the urethra 5, 7, 10, 12, 2 point continuous suture to relieve the tension, shorten the operation time, and reduce the occurrence of leakage of urine.
منابع مشابه
A New Approach for Quantitative Evaluation of Reconstruction Algorithms in SPECT
ABTRACT Background: In nuclear medicine, phantoms are mainly used to evaluate the overall performance of the imaging systems and practically there is no phantom exclusively designed for the evaluation of the software performance. In this study the Hoffman brain phantom was used for quantitative evaluation of reconstruction techniques. The phantom is modified to acquire t...
متن کاملTarget detection The Simulation Analysis of the Effect of Imaging Sidelap/Overlap on the Quality of 3D Reconstruction in UAV Photogrammetry and Determination of their Optimal Values
The selection of effective and optimal sidelap/overlap of images according to the quality, speed, cost and purpose of each UAV photogrammetric project is considered as an important parameter. Since two decades ago, several researches have been carried out based on a trial and error strategy for this purpose, in which different drones and cameras have been utilized for imaging with different sid...
متن کاملUltra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملDesign and Manipulation 3D Imaging System by using Photodiode Grid
Introduction: Radiation imaging is one of the applicable methods in diagnostic medicine and nondestructive testing for industrial applications. In nondestructive 3D imaging, in addition to the radiation source, there is a requirement for a suitable detection system, data acquisition system, mechanical sections for moving objects, reconstruction algorithm and finally a computer for processing an...
متن کاملFrom medical images to minimally invasive intervention: Computer assistance for robotic surgery
Minimally invasive surgery has been established as an important way forward in surgery for reducing patient trauma and hospitalization with improved prognosis. The introduction of robotic assistance enhances the manual dexterity and accuracy of instrument manipulation. Further development of the field in using pre- and intra-operative imaging guidance requires the integration of the general ana...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2014