Determining the accuracy of an eye tracking system for laser refractive surgery.
نویسندگان
چکیده
PURPOSE Patient eye and head movements during laser refractive surgery may result in errors between the surgical beam position and the desired location for optimum correction. This, in turn, may lead to reduced postoperative vision, including increased higher order aberrations of the eye. Active eye tracking systems are often incorporated into laser delivery systems, which aim to reduce the effect of patient eye movement. METHODS In this study, the accuracy of an eye tracking system designed for laser refractive surgery was determined. An enucleated porcine eye was attached to a scanning device and the movement measured using the eye tracking system. The recorded position is compared to the preprogrammed position of the scanning device. RESULTS The system demonstrated an accuracy of 0.06 m for an intact cornea and 0.1 mm for a cornea with a thin flap removed. This compares to an average decentration of ablation of 0.4 mm for patients relying on passive fixation, as measured by previous clinical trials. CONCLUSION implementation of this eye tracker would lead to improved alignment between the laser and eye during laser refractive surgery.
منابع مشابه
Refractive Surgery Feature Story
H uman eyes are capable of six types of movement: x/y lateral shifts, z levelling, horizontal and vertical rotations, and cyclotorsion (rotation around the optical axis). Current laser technology for refractive surgery creates corneal alterations to correct refractive errors more accurately than in the past.1 Ablation profiles are based on the removal of tissue lenticules through sequential las...
متن کاملThe Alcon/Summit/Autonomous perspective on fixed vs. variable spot ablation.
The LADARVision system utilizes a small fixed diameter excimer laser beam coupled with a high fidelity eye tracking system to perform wavefront-guided refractive surgery. The fixed small beam provides a consistent ablation per pulse. By delivering many identical pulses in a predetermined pattern, which includes an optimized custom blend zone, the laser is able to ablate complex (higher order) c...
متن کاملStudy of Optical Models Regarding the Human Eye
Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...
متن کاملمقایسه دو روش بیومتری التراسوند (Ultrasound) و لنستار (Lenstar) در تعیین طول محور چشم و میزان عیب انکساری پس از عمل جراحی کاتاراکت
Background and Objective: Ocular biometry refers to the measurement of the axial length of the eye and thickness of the intraocular structures. This process is routinely performed for all patients before cataract surgery. The accuracy of the biometric data is directly associated with the refractive status after cataract surgery. Currently, two methods of biometry, namely ultrasound and optical ...
متن کاملToday’s Practice Refractive Fundamentals
SEPTEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 85 Editor’s note: In last month’s Fundamentals column, Kathryn Masselam Hatch, MD; and Jonathan H. Talamo, MD, provided a comprehensive overview of excimer laser technology. Drs. Hatch and Talamo discussed basic concepts such as fluence, beam profile, ablation pattern, and eye tracking and registration to help readers optimize excimer la...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of refractive surgery
دوره 16 5 شماره
صفحات -
تاریخ انتشار 2000