Comparison of Transmit Coil Configurations for Multiple-Mouse MRI with Receive-Only Coils
نویسندگان
چکیده
Introduction In human MRI, it is common to use one radiofrequency coil to produce a homogeneous excitation field, but use a separate surface coil or array of coils for increased detection sensitivity. Multiple-mouse MRI (MMMRI) accelerates preclinical studies by imaging multiple mice simultaneously [1]. Although MMMRI was originally reported using an array of shielded transmit-receive (Tx-Rx) coils, it also stands to benefit from using dedicated Rx coils. While the Rx coils in such a MMMRI setup can be tailored to a specific application, there are only two competing configurations for the transmit coils: (A) separate, shielded Tx coils for each mouse; or (B) a single large Tx coil encompassing all mice. The objective of this work is to compare these two configurations on a 7T MMMRI Varian imaging system. Methods To compare Tx coil configurations, we tested the simple case of two imaging samples. In the first configuration (Fig. 1A), two shielded birdcage Tx coils (OD 60mm, ID 40mm, RAPID MR International) were mounted adjacent to one another. We constructed two diode-detunable saddle coils (ID 19mm) to serve as Rx coils. In the second configuration (Fig. 1B), two Tx coils were replaced with a single large-volume shielded birdcage Tx coil (OD 154mm, ID 135mm) of sufficient size to image at least 7 mice simultaneously. In each case, we acquired two sets of images, one with a full field-of-view (FOV), 102.4x38.4x25.6mm, covering both samples, and one with a reduced FOV, 38.4x19.2x25.6mm to cover a single sample. Images from the large FOV and from configuration A were reconstructed by standard Fourier transform methods. For the small FOV images in case B, a modified sensitivity-encoding (SENSE) reconstruction was used [1, 2], wherein the coil sensitivity was taken as a constant for all pixels (corresponding to our observation that aliased ghosts were primarily due to electromagnetic coupling with an effective g factor of 1.2). Images were acquired using a 3D gradient echo with parameters: TE/TR = 5.4/250 ms, matrix 384x256x64 (large FOV) and 384x192x256 (small FOV) and scan time of 27mins (large FOV) and 1hr22mins (small FOV). Large FOV images were used to quantify ghosts and determine coil sensitivity. Small FOV images represented the desired high-resolution acquisition were used for SNR measurements.
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کامل3-D RF Coil Design Considerations for MRI
High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...
متن کاملIn vivo multiple-mouse MRI at 7 Tesla.
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost ar...
متن کاملDesign and comparison of two eight-channel transmit/receive radiofrequency arrays for in vivo rodent imaging on a 7 T human whole-body MRI system.
PURPOSE Magnetic resonance imaging (MRI) of rodents can be expected to be a growing application, particularly when translatory imaging research "from mouse to man" is envisioned. 7 T high-field human whole-body MR systems provide a powerful platform for high-resolution small animal imaging. For achieving adequate spatial resolution, dedicated radiofrequency coils have to be designed to provide ...
متن کاملGeometrically Decoupled Phased Array Coils for Mouse Imaging
Introduction: Roemer et al [1] introduced phased array surface coils which offer high SNR over a large field of view. Phased array volume coils, introduced by Hayes et al [2] have high SNR at the surface and centre of the volume. Most array coil designs typically employ a combination of geometrical and additional techniques, such as isolating preamplifiers, for element-to-element decoupling. Th...