Interscan displacement-induced variance in PET activation data is excluded by a scan-specific attenuation correction.

نویسندگان

  • A A T S Reinders
  • A T M Willemsen
  • J R Georgiadis
  • M Hovius
  • A M J Paans
  • J A den Boer
چکیده

In PET activation studies, linear changes in regional cerebral blood flow may be caused by subject interscan displacements rather than by changes in cognitive state. The aim of this study was to investigate the impact of these artifacts and to assess whether they can be removed by applying a scan-specific calculated attenuation correction (CAC) instead of the default measured attenuation correction (MAC). Two independent data sets were analyzed, one with large (data I) and one with small (data II) interscan displacements. After attenuation correction (CAC or MAC), data were analyzed using SPM99. Interscan displacement parameters (IDP), obtained during scan realignment, were included as additional regressors in the General Linear Model and their impact was assessed by variance statistics revealing the affected brain volume. For data I, this volume reduced dramatically from 579 to 12 cm(3) (approximately 50-fold) at P(uncorr) </= 0.001 and from 100 to 0 cm(3) at P(corr) </= 0.05 when CAC was applied instead of MAC. Surprisingly, for data II, applying CAC instead of MAC still resulted in a substantial (approximately 10-fold) reduction of the affected volume from 23 to 2 cm(3) at P(uncorr) </= 0.001. We conclude that interscan displacement-induced variance can be prevented by applying a (realigned attenuation correction scan (e.g., CAC). With MAC data, introducing IDP covariates is not an alternative since they model only this variance. Even in data with minor interscan displacements, applying a (realigned attenuation correction method (e.g., CAC) is superior to a nonaligned MAC with IDP covariates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

Estimation of fetal absorbed dose from low-dose attenuation-correction CT in PET / CT imaging by using the Body Builder Phantom

One of the methods of studying the physiology and metabolism of important tissues such as the heart, brain and cancer tumors is the use of PET/CT System. A small number of patients are pregnant women who undergo a PET/CT scan due to lack of knowledge about pregnancy or due to dire clinical need. The final dose received by the fetus is based on three factors: the absorbed dose of the fetal tissu...

متن کامل

Common artifacts in PET myocardial perfusion images due to attenuation-emission misregistration: clinical significance, causes, and solutions.

UNLABELLED Misregistration between attenuation and emission images causes artifactual abnormalities on cardiac PET images that result in false-positive defects. This study determines the frequency and mechanisms of misregistration artifacts, identifies their predictors, and validates a method for their routine clinical identification, prevention, or correction. METHODS We performed 1177 conse...

متن کامل

CT Attenuation Correction in PET/CT Image Fusion

This paper presents the results of evaluating the use of X-ray CT data for attenuation correction of PET data. This method of attenuation correction is intended for use with a combined volume-imaging PET/CT scanner for oncology. We discuss four possible methods of scaling the attenuation map from the CT energies to the required PET attenuation map at 511 keV. Results are presented on the testin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2002