Loss of RNase R induces competence development in Legionella pneumophila.

نویسندگان

  • Xavier Charpentier
  • Sébastien P Faucher
  • Sergey Kalachikov
  • Howard A Shuman
چکیده

RNase R is a processive 3'-5' exoribonuclease with a high degree of conservation in prokaryotes. Although some bacteria possess additional hydrolytic 3'-5' exoribonucleases such as RNase II, RNase R was found to be the only predicted one in the facultative intracellular pathogen Legionella pneumophila. This provided a unique opportunity to study the role of RNase R in the absence of an additional RNase with similar enzymatic activity. We investigated the role of RNase R in the biology of Legionella pneumophila under various conditions and performed gene expression profiling using microarrays. At optimal growth temperature, the loss of RNase R had no major consequence on bacterial growth and had a moderate impact on normal gene regulation. However, at a lower temperature, the loss of RNase R had a significant impact on bacterial growth and resulted in the accumulation of structured RNA degradation products. Concurrently, gene regulation was affected and specifically resulted in an increased expression of the competence regulon. Loss of the exoribonuclease activity of RNase R was sufficient to induce competence development, a genetically programmed process normally triggered as a response to environmental stimuli. The temperature-dependent expression of competence genes in the rnr mutant was found to be independent of previously identified competence regulators in Legionella pneumophila. We suggest that a physiological role of RNase R is to eliminate structured RNA molecules that are stabilized by low temperature, which in turn may affect regulatory networks, compromising adaptation to cold and thus resulting in decreased viability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Legionella Pneumophila bacteria in hospital water supply systems

Introduction: Legionella Pneumophila bacteria is known as one of the most important nosocomial infections and the most common cause of death in patients. This study was aimed to identify Legionella Pneumophila bacteria in hospital water supply systems. Material and Methods: This descriptive cross-sectional study was performed to identify Legionella pneumophila in hot and cold-water systems of i...

متن کامل

The Different Antibacterial Impact of Silver Nanoparticles Against Legionella pneumophila Compared to Other Microorganisms

Legionella pneumophila is the pathogen responsible for severe pneumonia known as Legionnaires’ disease. Legionella can live under varied stress conditions, especially in cold environments, and is common in many artificial environments. In this study, the antimicrobial activity of biogenic silver nanoparticles, prepared using the culture supernatant of Klebsiella pneumoniae, was evaluated agains...

متن کامل

An Investigation of the Legionella Pneumophila Infection in Pneumonic Patients in Three Different Infections Hospital Wards in Tehran

Legionella pneumophila is one of the causative agent of pneumonia in human being. In recent years many reports has been come from different parts of world regarding infectivity of this organism. This disease occurs almost because of contamination of air conditioning systems. For the purpose of assessment of the legionella pneumophila in pneumonic patients, 200 specimen from sputum and tracheo-b...

متن کامل

Isolation of Legionella pneumophila from Tehran Hospital Water Samples

Over a Period of three months (summer), 108 samples of water collected from four hospitals in Te-hran. They were taken from numerous potable and non-potable water, including main supply cis-terns, calorifiers, hot and cold tap water, shower, cooling tower and drain of air condition system. Culturing of concentrated and non-concentrated water samples on Buffered Charcoal Yeast Extract (BCYE) Aga...

متن کامل

Isolation of Legionella Pneumophila Serogroups 1, 8 & 10 (Causative Agents of Legionnaires\' Disease) from Water Sources in Tehran, Iran

In this survey, 187 samples collected from 9 different sources of water in Tehran such as: water cool‌ers, neonates incubators, water bathes (37° C), little pools in parks or squares, cooling towers, hot or cold water taps, were examined for Legionnaires' disease agents. Inoculating water samples on selec‌tive and nonselective media resulted in isolation of several strains of gram negative bact...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of bacteriology

دوره 190 24  شماره 

صفحات  -

تاریخ انتشار 2008