[Reconstruction of the right ventricular outflow tract using a Medtronic Freestyle aortic root bioprosthesis].
نویسندگان
چکیده
Uncorrected, long-term pulmonary regurgitation leads to right ventricular dilatation and dysfunction in a significant percentage of patients. We used magnetic resonance imaging (MRI) before and after surgery to assess the effect of pulmonary valve replacement with the Medtronic Freestyle bioprosthesis on right ventricular function and volume in nine patients with pulmonary regurgitation or stenosis. Mean follow-up time was 26 (10) months. We observed a decrease in mean end-diastolic volume from 143.6 (85.1) mL/m2 to 74.1 (12.6) mL/m2 (P=.018) and, in end-systolic volume from 88.0 (50.3) mL/m2 to 35.8 (19.3) mL/m2 (P=.016). In pulmonary valve disease, extensive follow-up by MRI is essential for timely evaluation of the degree of right ventricular dilation or dysfunction and for selecting a suitable time for valve replacement. The Medtronic Freestyle bioprosthesis is a good surgical choice for pulmonary valve replacement as its use is associated with low morbidity and mortality and the successful normalization of ventricular volumes.
منابع مشابه
Infectious false aneurysm of the right ventricular outflow tract after repair of congenital heart defect treated with Freestyle aortic bioprosthesis.
OBJECTIVES False aneurysm of the right ventricular outflow tract (RVOT) is one of complications after surgery of congenital heart disease. It is controversial about materials for reconstruction of RVOT in this setting, when associated with pulmonary hypertension or bacterial infection. Pulmonary homograft seems to be the first choice, but its availability is extremely limited in Japan. METHOD...
متن کاملAortic Root Replacement for Pseudoaneurysm Arising from Freestyle Aortic Bioprosthesis.
A 70-year-old female presented with a new systolic murmur and shortness of breath three years after undergoing aortic root replacement using a 27-mm Medtronic Freestyle® stentless full root bioprosthesis (Medtronic, Inc., Fridley, Minnesota, USA). A large complex aortic root pseudoaneurysm was identified on contrasted computed tomography of the chest and transesophageal echocardiogram. We descr...
متن کاملStructural Valve Deterioration After Aortic Valve Replacement with Medtronic Freestyle Stentless Porcine Aortic Root Bioprostheses
The Medtronic freestyle aortic root bioprosthesis (Medtronic, Inc., Minneapolis, MN, USA) is a stentless valve with an effective orifice area that is larger than that observed on other bioprostheses. However, there have been sporadic reports of structural valve deterioration (SVD), such as aortic root wall rupture, leaflet tearing, and pseudoaneurysm formation. We report five cases of SVD of fr...
متن کاملThe freestyle valve as a right ventricle to pulmonary artery conduit. A systematic review and meta-analysis
INTRODUCTION Reconstruction of the right ventricular outflow tract is the most commonly performed valve repair/replacement procedure in congenital cardiac surgery. There is an ongoing shortage of homografts, and existing bioprosthetic options suffer from substantial rates of structural valve deterioration over time. The Medtronic Freestyle valve is used extensively in the aortic position, but l...
متن کاملAnesthesiology management for the transcatheter aortic valve implantation
Methods All procedures were performed in period between March 2011 and May 2013.In that period, 26 procedures performed in patients with severe aortic stenosis: of total, sixteen patents received Medtronic/CORE valve. Ten patients received Edwards/Sapien Aortic Bioprosthesis, of which, one implanted by transaortic way. The average age was 78.43 years. In premedication, all received midazolam 5 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cardiologia
دوره 60 6 شماره
صفحات -
تاریخ انتشار 2007