Upgraded Optics for Sirius with Improved Matching of Electron and Photon Beam Emittances
نویسندگان
چکیده
A new optics has been designed for Sirius with improved betatron function matching in the 6 meter-long low beta straight sections for insertion devices. Both horizontal and vertical betatron functions are set to 1.5 m in the center of the section, improving the matching of the electron and undulator photon beams. In addition, the horizontal beam stay clear has also been reduced allowing for small horizontal gap devices as well as the conventional small vertical gap ones. The new design optics has been optimized to the same previous performance regarding dynamic aperture and momentum acceptance.
منابع مشابه
Comparison of two radiation techniques in breast boost delivery
Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...
متن کاملGenerating a Homogeneous Dose Distribution in the Junction Region between Two Adjacent Fields in Electron Beam Therapy
Introduction: Treatment with megavoltage electron beams is ideal for irradiating superficial tumors because of their limited range in tissues. However, for electron treatment of extended areas, such as the chest wall, two or more adjacent fields can be used. Abutment of these fields may lead to significant dose in homogeneities in the junction region. The aim of this study is to offer a new met...
متن کاملUltimate luminosities and energies of photon colliders ∗
A photon collider luminosity and its energy are determined by the parameters of an electron-electron linear collider (energy, power, beam emittances) and collision effects. The main collision effect is the coherent e+e− pair creation. At low energies (2E< 0.5–1 TeV) this process is suppressed due to repulsion of electron beams. In this region Lγγ(z > 0.65) ≥ 1035cm−2s−1 is possible (1033 − 1034...
متن کاملDosimetric Evaluation of Target Volume in Breast Boost Radiotherapy: Comparison of Electron and Photon Beam
Background and purpose: Breast‑conserving surgery followed by radiation therapy to the whole breast is now recognized as a standard strategy in patients with breast cancer. Recommended technique for radiotherapy is whole breast irradiation followed by boost to the tumor bed. This study aimed to compare the dosimetric parameters of electron and photon beams for boosting irradiation in post‑lump...
متن کاملBenchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -