Pulse oximetry during intraaortic balloon pump application.
نویسندگان
چکیده
BACKGROUND Pulse oximeters are multiple used devices in anaesthesiology and intensive care medicine and must provide reliable data during various conditions of signal interference, including light, motion and reduced perfusion. The aim of this study was to evaluate the reliability of different new-generation pulse oximeters during intraaortic balloon pump (IABP) therapy. METHODS In the experimental setting, the validity of three pulse oximetry technologies (Masimo Radical 7, Nellcor N-600 and Datex Ohmeda TruSat) was evaluated in patients with IABP treatment. Arterial blood gas analysis (BGA-SaO2) data were compared with the pulse oximetric values (SpO2) during 1:1, 1:2 and 1:3 support ratio. RESULTS The mean differences (bias) during 1:1, 1:2 and 1:3 IABP support between BGA-SaO2 and Datex-SpO2 were 3.38% [95% confidence intervals (CI):±1.39%], 1.41% (95% CI 1.14%) and 2.10% (95% CI:±0.94%), respectively. Between BGA-SaO2 and Nellcor-SpO2, a bias of 0.77% (95% CI:±0.46%), 0.85% (95% CI:±0.40%) and 0.59% (95% CI:±0.38%) was found. In the comparison of BGA-SaO2 and Masimo-SpO2, a bias of 0.58% (95% CI:±0.56%), 0.19% (95% CI:±0.40%) and -0.01% (95% CI:±0.43%) was found, respectively. CONCLUSIONS In patients with IABP support, the pulse oximetric values of the Masimo Radical 7 are accurate in 1:2 and 1:3 support ratio compared with blood gas analysis. In these support ratios, the Masimo Radical 7 is superior to the Nellcor N-600. The Datex Ohmeda TruSat showed a significant difference between the measured pulse oximetric values and blood gas analysis in all support ratios.
منابع مشابه
Influence of timing of intraaortic balloon placement in cardiac surgical patients.
OBJECTIVE The study objective was to evaluate the association between timing of intraaortic balloon pump insertion and outcomes in patients undergoing cardiac surgery. METHODS All patients aged 18 years or more who underwent coronary artery bypass surgery, cardiac valve surgery, or thoracic aortic surgery between January 2002 and December 2007 were included. Data were obtained from cardiac su...
متن کاملHow much of the intraaortic balloon volume is displaced toward the coronary circulation?
OBJECTIVE During intraaortic balloon inflation, blood volume is displaced toward the heart (V(tip)), traveling retrograde in the descending aorta, passing by the arch vessels, reaching the aortic root (V(root)), and eventually perfusing the coronary circulation (V(cor)). V(cor) leads to coronary flow augmentation, one of the main benefits of the intraaortic balloon pump. The aim of this study w...
متن کاملParaplegia associated with intraaortic balloon pump counterpulsation.
Two patients developed paraplegia associated with the use of the intraaortic balloon pump. In one patient, transient spinal ischemic episodes ceased after removal of the intraaortic balloon and the second patient apparently sustained spinal cord infarction. Possible etiologic mechanisms include vascular occlusion due to balloon position, arterial spasm, thromboembolic phenomena, hypotension, hy...
متن کاملIntra aortic balloon pump: literature review of risk factors related to complications of the intraaortic balloon pump
The increasing use of the intra aortic balloon pump is attributed to the relatively easy percutaneous insertion and the low threshold of use over the past few years, especially in elderly patients with multi-vessel diseases and an affected ejection fraction.Unfortunately, the clinical assessment of the complications associated to the use of this supporting device, underestimates the frequency o...
متن کاملBasic principles of the intraaortic balloon pump and mechanisms affecting its performance.
The intraaortic balloon pump (IABP) is the single most effective and widely used device for temporary mechanical assistance of the failing heart. Although the principles underlying IABP function are simple, various biologic factors often determine its performance in a particularly complicated way. We briefly describe the basic disciplines of counterpulsation by IABP and the induced hemodynamic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta anaesthesiologica Scandinavica
دوره 55 3 شماره
صفحات -
تاریخ انتشار 2011