Development of a standard swine hemorrhage model for efficacy assessment of topical hemostatic agents.

نویسندگان

  • Bijan S Kheirabadi
  • Françoise Arnaud
  • Richard McCarron
  • Alan D Murdock
  • Douglas L Hodge
  • Brandi Ritter
  • Michael A Dubick
  • Lorne H Blackbourne
چکیده

BACKGROUND The diverse information of efficacy of hemostatic products, obtained from different military laboratories using different models, has made it difficult to ascertain the true benefit of new hemostatic agents in military medicine. The aim of this study was to recommend a standard hemorrhage model for efficacy testing acceptable by most investigators in the field and avoid contradictory and duplicative efforts by different laboratories. METHODS The swine femoral artery injury model (6-mm arteriotomy) with some modifications was tested to standardize the model. The suggested modifications included no splenectomy, one-time treatment, 30 seconds free bleeding, and 5 L limit for fluid resuscitation. The model was tested with all or some of these modifications in four experimental conditions (n = 5-6 pigs per condition) using Combat Gauze (CG) as control agent. RESULTS The primary end points including blood pressure, blood loss, and survival rates were modestly changed in the four conditions. The second experimental condition in which bleeding was treated with a single CG with 3-minute compression produced the most suitable results. The average blood loss was 99 mL/kg, and hemostasis was achieved in one-third of the pigs, which led to matching survival rate. CONCLUSION A rigorous hemorrhage model was developed for future evaluation of new hemostatic agents and comparison with CG, the current standard of care. This model may not be suitable for testing every agent and some modifications may be necessary for specific applications. Furthermore, laboratory studies using this or similar models must be accompanied by operational testing in the field to confirm the efficacy and practical utility of selected agents when used on the battlefield.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه اثر کلسیم سولفات و کلرید فریک در کنترل خونریزی طی جراحی کبدی؛ مطالعه مدل حیوانی

Background and Objective: The control of parenchymal hemorrhage especially in liver parenchyma, despite improvements in surgical science, is still one of the challenges that surgeons are facing with. Therefore, introducing an effective method to control liver bleeding is of important research priority. This study aimed to compare the hemostatic effect of calcium sulfate and ferric chloride on c...

متن کامل

Comparative testing of new hemostatic agents in a swine model of extremity arterial and venous hemorrhage.

OBJECTIVE To compare advanced hemostatic dressings: HemCon (HC), QuikClot ACS+ (advanced clotting sponge, and two granular agents: Celox (CX) and WoundStat (WS), with a standard field dressing in a swine model of extremity hemorrhage. METHODS We randomized 30 animals to treatment with a standard dressing or a hemostatic agent applied to a 2 x 6-mm injury in the femoral artery and vein after 4...

متن کامل

Determination of efficacy of novel modified chitosan sponge dressing in a lethal arterial injury model in swine.

BACKGROUND Chitosan is a functional biopolymer that has been widely used as a hemostat. Recently, its efficacy has been questioned due to clinical failures as a result of poor adhesiveness. The purpose of this study was to compare, in a severe groin injury model in swine, the hemostatic properties of an unmodified standard chitosan sponge with standard gauze dressing and a novel hydrophobically...

متن کامل

Comparison of Topical Hemostatic Agents in a Swine Model of Extremity Arterial Hemorrhage: BloodSTOP iX Battle Matrix vs. QuikClot Combat Gauze

BloodSTOP iX Battle Matrix (BM) and QuikClot Combat Gauze (CG) have both been used to treat traumatic bleeding. The purpose of this study was to examine the efficacy and initial safety of both products in a swine extremity arterial hemorrhage model, which mimics combat injury. Swine (37.13 ± 0.56 kg, NBM = 11, NCG = 9) were anesthetized and splenectomized. We then isolated the femoral arteries ...

متن کامل

Topical hemostatic agents in liver surgery: do we need them?

Background: Worldwide, partial liver resections are increasingly performed for primary or secondary hepatic malignancies. There are various techniques to reduce blood loss during liver surgery. Several topical hemostatic agents have been developed to improve hemostasis of the resection surface and these agents are used more and more, even although the true effects remain unclear. Methods: The p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of trauma

دوره 71 1 Suppl  شماره 

صفحات  -

تاریخ انتشار 2011