Interpreting Radiation Treatment Planning Study Results: A Note of Caution

نویسنده

  • Dipankar Kandel
چکیده

Email:[email protected] Prostate cancer is the most commonly diagnosed cancer among males in the United States.1 The treatment of prostate cancer has several options, including external beam radiation therapy. The primary goal of radiation therapy is to control the tumor by delivering a maximum dose to the tumor site, yet minimizing the radiation dose to normal tissues. The development of advanced delivery techniques such as intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) as well as more accurate treatment planning systems have improved tumor control in radiation therapy. Intensity modulated radiation therapy is a treatment technique that delivers the radiation beam in a static mode, whereas VMAT is considered to be a rotational IMRT that allows the beam to be delivered with the gantry of the machine rotating around the patient.2 Sophisticated treatment planning systems have also increased the accuracy of dose calculation and improved the work flow in the clinic. The results from different complex delivery techniques, however, may vary from one institution to another. The main purpose of this article is to provide a brief summary of the reasons that may have caused discrepancies among different treatment planning studies on prostate cancer. This study reviewed the most recent literature on prostate cancer treatment planning. The literature search was conducted using the terms “prostate cancer”, “IMRT”, and “VMAT” on Google Scholar. According to the review, the common agreement among different studies was the decreased treatment time and less number of monitor units (MUs) associated with VMAT when compared to IMRT.3-14 There were discrepancies in dosimetric results for organs at risk (OARs)among different authors.3-14 For example, Kjaer-Kristoffersen et al.3 reported that VMAT had the capability to produce better or equal sparing of OARs than IMRT. In contrast, Yoo et al.4 reported that IMRT was better in sparing OARs than VMAT. Zhang et al.5 showed that VMAT was better than IMRT in sparing the rectal wall. In a study by Tsai et al.,6 there

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of treatment planning system using simulation PRIMO code.

Introduction: In radiation therapy, in order to double-check the dosimetric results of the main treatment planning system (TPS), a distinct TPS, with few capacitances in terms of contouring and a variety of dose calculation algorithms is used. This system has the capability to double check the planification and the accurate prediction of dose distribution in order to be ensured...

متن کامل

Integrating fMRI data into 3D conventional radiotherapy treatmentplanning of brain tumors

Introduction: This study was aimed to investigate the beneficial effects of functional magnetic resonance imaging (fMRI) data in treatment planning for patients with CNS tumors in order to decrease the injury of functional regions of the brain followed by increase in life quality and survival of patients. This study pursues a novel approach in planning for the treatment of brai...

متن کامل

An Approach in Radiation Therapy Treatment Planning: A Fast, GPU-Based Monte Carlo Method

Introduction: An accurate and fast radiation dose calculation is essential for successful radiation radiotherapy. The aim of this study was to implement a new graphic processing unit (GPU) based radiation therapy treatment planning for accurate and fast dose calculation in radiotherapy centers. Materials and Methods: A program was written for parallel runnin...

متن کامل

The Comparison 2D and 3D Treatment Planning in Breast Cancer Radiotherapy with Emphasis on Dose Homogeneity and Lung Dose

Introduction: Breast conserving radiotherapy is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is usually used for this purpose. This technique is performed using 2D or 3D treatment planning systems. The aim of this study was to compare 2D treatment planning with 3D treatment planning in tangential irradiation in breast conse...

متن کامل

Comparison of Absorbed Dose in Thyroid and Lens as Organs at Risk Between in vivo Dosimetry and 3-D Treatment Planning Calculation in Head and Neck Radiotherapy by Linac Beam

Introduction: Critical organs and structures may receive significant amounts of irradiation even if they are not the target of radiotherapy or located outside the treatment field. Although the sensitive thyroid gland and lens are not directly the targets of treatment, they can be affected by irradiation during the treatment of tumours in head and neck region. The purpose of thi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014