Predictors of thrombosis in hepatic vasculature during microwave tumor ablation of an in vivo porcine model.
نویسندگان
چکیده
PURPOSE To evaluate and model the risk of in vivo thrombosis in each hepatic vessel type during hepatic microwave ablation as a function of vessel diameter, velocity, and vessel-antenna spacing. MATERIALS AND METHODS A single microwave ablation antenna was inserted into a single porcine lobe (n = 15 total) adjacent to a hepatic artery, hepatic vein, or portal vein branch. Conventional ultrasound and Doppler ultrasound were used to measure the vessel diameter, blood flow velocity, and vessel-antenna spacing. A microwave ablation zone was created at 100 W for 5 minutes. Thrombus formation was evaluated on ultrasound performed immediately after the procedure. Logistic regression was used to evaluate the predictive value of vessel diameter, blood flow velocity, and vessel-antenna spacing on vascular thrombosis. RESULTS Thrombosis was identified in 53% of portal veins, 13% of hepatic veins, and 0% of hepatic arteries. The average peak blood flow rate of the hepatic artery was significantly greater than the average peak blood flow rate of the hepatic vein and portal vein. Peak blood flow velocity < 12.45 cm/s, vessel diameter < 5.10 mm, and vessel-antenna spacing < 3.75 mm were strong predictors of hepatic vein thrombosis. However, these individual factors were not predictive of the more common portal vein thrombosis. CONCLUSIONS Hepatic arteries do not appear to be at risk for thrombosis during microwave ablation procedures. Portal vein thrombosis was more common than hepatic vein thrombosis during microwave ablation treatments but was not as predictable based on vessel diameter, flow velocity, or vessel-antenna spacing alone.
منابع مشابه
Optimization of a Novel Microwave Tumor Ablation System in an in Vivo Porcine Liver Model
Background Radiofrequency (RF) ablation is commonly used in the treatment of surgically unresectable hepatic tumors. It is amenable to open, laparoscopic, or percutaneous application, it makes use of well-understood principles of electrical and thermal heating of tissue, and it is readily available. However, local recurrence rates following RF ablation are as high as 39%. Microwave (MW) ablatio...
متن کاملPET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors
Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...
متن کاملMicrowave Tumor Ablation of Vertebral Bone Metastasis: A Case Report
Introduction: Thermal ablation by microwave (MWA) has proven efficacy in treatment of primary and metastatic cancers. Soft tissue tumors could be ablated completely using MWA. However, bony tissue metastasis particularly spinal vertebral metastasis ablation has not reported yet. Case presentation: A 50 year old male patient with primary diagnosed colon cancer undergone surgical resection of ...
متن کاملEvaluation of a Novel Thermal Accelerant for Augmentation of Microwave Energy during Image-guided Tumor Ablation
The primary challenge in thermal ablation of liver tumors (e.g. hepatocellular carcinoma and hepatic colorectal cancer) is the relatively high recurrence rate (~30%) for which incomplete ablation at the periphery of the tumor is the most common reason. In an attempt to overcome this, we have developed a novel thermal accelerant (TA) agent capable of augmenting microwave energy from a distance n...
متن کاملNumerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of vascular and interventional radiology : JVIR
دوره 25 12 شماره
صفحات -
تاریخ انتشار 2014